Descargar Imprimir esta página

SICK MLG-2 WebChecker Manual De Instrucciones página 7

Ocultar thumbs Ver también para MLG-2 WebChecker:

Publicidad

Byte
8
Name
Output Function 5
Type
UInt16
Byte
12
Name
Output Function 7
Type
UInt16
Byte
16
Name
Output Function 9
Type
UInt16
Byte
20
Name
Output Function 11
Type
UInt16
Byte
24
Name
Output Function 13
Type
UInt16
Byte
28
Name
Output Function 15
Type
UInt16
Process Data Out
Byte
Name
Type
5 Troubleshooting
Störungsbehebung
Eliminazione difetti
Élimination des défauts
Resolución de problemas
故障排除
en
Meaning
Sender LED
Supply voltage off or too low
All o
Hardware error
Red O
Sensor teach-in or material
teach-in error
QoR-alarm
Sync error
Short-circuit
Meaning
Measure
Supply voltage off or too low
Check the supply voltage.
Hardware error
Contact Service.
Sensor teach-in error
Check that the front screens are clean.
Ensure that all light beams are unobstructed during
teach-in.
Check the alignment of the sender and receiver with
each other. Perform alignment again.
Perform sensor teach-in again.
Check "Blanking" in the SOPAS settings in the menu.
Material teach-in error
8023955.16YM // 24.02.2020
9
10
Output Function 6
UInt16
13
14
Output Function 8
UInt16
17
18
Output Function 10
UInt16
21
22
Output Function 12
UInt16
25
26
Output Function 14
UInt16
29
30
Output Function 16
UInt16
0
Process Data Out
UInt16
Receiver LED
Control panel LED
All o
All o
Red O
Red Ö 10 Hz +
Alignment: Ö 10 Hz
Yellow o +
RS-485 /
Green o
IO-Link: Ö 10 Hz
Alignment
Yellow Ö 3 Hz +
Ö 3 Hz
Green O
Red O + Yellow
O
Red O + Green
O
No material is located between the sender and receiver.
The material is transparent.
Check "Blanking" and "Material teach-in" in the SOPAS
settings in the menu.
Meaning
11
QoR-alarm
Sync error
15
Short-circuit
de
19
Bedeutung
Versorgungsspannung aus oder
zu gering
Hardwarefehler
23
Sensor-Teach-in oder
Material-Teach-in Fehler
QoR-Alarm
27
Sync-Fehler
Kurzschluss
Bedeutung
31
Versorgungsspannung aus oder
zu gering
Hardwarefehler
Sensor-Teach-in-Fehler
Material-Teach-in-Fehler
QoR-Alarm
Sync-Fehler
Kurzschluss
it
Significato
Tensione di alimentazione assente
o troppo bassa
Difetto hardware
Errore teach-in sensore o teach-in
materiale
Allarme QoR
Errore di sincronizzazione
Corto circuito
Measure
Clean the sensor.
Check alignment.
Check the quality of the material
Check the electrical connection.
Check the electrical cables for breakage.
Contact Service. Replace the device.
LED Sender
LED Empfänger
LED Bedienfeld
Alle o
Alle o
Alle o
Rot O
Rot O
Rot Ö 10 Hz
Alignment: Ö 10 Hz
+ Gelb o +
RS-485 /
Grün o
IO-Link: Ö 10 Hz
Alignment
Gelb Ö 3 Hz +
Ö 3 Hz
Grün O
Rot O + Gelb O
Rot O + Grün O
Maßnahme
Versorgungsspannung prüfen.
Service kontaktieren.
Frontscheiben auf Sauberkeit prüfen.
Sicherstellen, dass während dem Teach-in alle Lichts-
trahlen frei sind.
Ausrichtung Sender und Empfänger zueinander prüfen.
Alignment erneut durchführen.
Sensor-Teach-in erneut durchführen.
In SOPAS Einstellungen im Menü „Ausblendung" prüfen.
Zwischen Sender und Empfänger liegt kein Material.
Das Material ist transparent.
In SOPAS Einstellungen im Menü „Ausblendung" und
„Material-Teach-in" prüfen.
Sensor reinigen.
Ausrichtung prüfen.
Qualität des Materials prüfen
Elektrischen Anschluss prüfen.
Elektrische Leitungen auf Kabelbruch prüfen.
Service kontaktieren. Gerät ersetzen.
Emettitore
Ricevitore LED
Pannello di controllo
LED
del LED
Tutti o
Tutti o
Tutti o
Rosso O
Rosso O
Rosso Ö 10 Hz
Alignment: Ö 10 Hz
+ Giallo o +
RS-485 /
Verde o
IO-Link: Ö 10 Hz
Giallo Ö 3 Hz +
Alignment Ö 3 Hz
Verde O
Rosso O +
Giallo O
Rosso O +
Verde O