NOTE: The log splitter is filled to the proper operating level from the
manufacturer with Shell Tellus® S2 M 32 Hydraulic Fluid. However, you
MUST check the fluid level before operating. If not filled, proceed with the
following steps:
WARNING
Much of the original fluid has been drawn into the cylinder and hoses.
Make certain to refill the reservoir to prevent damage to the hydraulic
pump.
3.
Check the fluid level using the dipstick. See Figure 8. Do not
overfill.
4.
Replace the vented dipstick securely, tightening it until the top of
the threads are flush with top of the pipe.
5.
Disconnect the spark plug and prime the pump by pulling the
recoil starter as far as it will go. Repeat approximately 10 times.
6.
Reconnect the spark plug wire and start the engine following the
instructions in the Operation section.
7.
Use the control handle to engage the wedge to the farthest
extended position. Then retract the wedge.
8.
Refill the tank as specified on the dipstick.
NOTE: Failure to refill the tank will void the splitter's warranty.
9.
Extend and retract the wedge 12 complete cycles to remove any
air trapped in the system (the system is "self-bleeding").
10. Refill the reservoir within the range marked on the dipstick.
NOTE: Some fluid may overflow from the vent plug as the system
builds heat and the fluid expands and seeks a balanced level.