Resumen de contenidos para HT 53/05

  • Página 1 manuals and user guides at all-guides.c...
  • Página 2 manuals and user guides at all-guides.c...
  • Página 3 manuals and user guides at all-guides.c Indice generale General index Índice general ITALIANO IT - 1 ENGLISH EN - 1 ESPAÑOL ES – 1...
  • Página 4 manuals and user guides at all-guides.c...
  • Página 5 manuals and user guides at all-guides.c ITALIANO Manuale d’uso...
  • Página 6 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 INDICE: PRECAUZIONI E PROCEDURE DI SICUREZZA 2 1.1. INTRODUZIONE 1.2. DURANTE L’USO 1.3. DOPO L’USO DESCRIZIONE PREPARAZIONE PER L’USO 3.1. TENSIONE DI ALIMENTAZIONE 3.2. CALIBRAZIONE 3.3. STOCCAGGIO FUNZIONAMENTO 4.1.
  • Página 7 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 PRECAUZIONI E PROCEDURE DI SICUREZZA Per la sicurezza dell’operatore e dello strumento si raccomanda di osservare scrupolosamente le procedure descritte presente manuale leggere attentamente le note precedute dal simbolo Non sottoporre lo strumento a shock meccanici.
  • Página 8 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 1.1. INTRODUZIONE Questo strumento é stato progettato per eseguire misure di luminosità. Assicurarsi che le batterie siano inserite Output Voltage correttamente. Select Switch 0.2V Un commutatore interno permette all’operatore di selezionare il fondo scala tra i valori 2V e 0.2V.
  • Página 9 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 2. DESCRIZIONE I luxmetri convertono la luminosità in tensione. Le sonde sono alimentate a batteria e progettate per fornire una lettura diretta quando il luxmetro viene collegato ad un multimetro digitale ad alta impedenza che accetti connettori a banana (HT53) o connettori Hypertac (HT53/05) e abbia una risoluzione di 1mV...
  • Página 10 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 3.3. STOCCAGGIO Per garantire la precisione delle misure, prima di utilizzare lo strumento dopo un periodo stoccaggio condizioni ambientali estreme, attendere che lo strumento torni alle normali condizioni di misura (v.
  • Página 11 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 4.2. MISURE DI LUMINOSITA’ ATTENZIONE massima tensione ingresso è 10 VRMS. Non applicare tensioni superiori onde evitare rischi di shock elettrici danni allo strumento. La sonda ha un commutatore a quattro posizioni.
  • Página 12 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 5.2. CONTROLLO DELLA BATTERIA 1. Sostituire batteria quando accende il LED “LOW BATT”. 2. Lo stato della batteria può essere controllato con un multimetro. Per fare ciò, posizionare il commutatore su OFF, collegare la sonda al multimetro posizionare multimetro...
  • Página 13 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 6. SPECIFICHE TECNICHE 6.1. CARATTERISTICHE La precisione si riferisce alle seguenti condizioni: 23°C±5°C con RH<80% 6.1.1. Misura di lux Campo di misura: 0.00~20.00lux 0~2000lux 10~20000lux Precisione: ±(3%rdg + 5mV) per CIE standard illuminante A (2856k) Precisione spettrale (f1’): ≤...
  • Página 14 manuals and user guides at all-guides.c HT53 HT53/05 Versione IT 1.01 – 19/04/2002 Impedenza di uscita: circa 500Ω Impedenza di ingresso del multimetro: minimo 1 Mohm (a 2V) Massima capacità di uscita: 4V DC Formule di conversione fotometriche: 1lux (lumen/metro =0.0929 candele inglesi 1 candela inglese =10.76 lux (lumen/metro...
  • Página 15 manuals and user guides at all-guides.c ENGLISH User manual...
  • Página 16 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 CONTENTS: SAFETY PRECAUTION AND PROCEDURES 1.1. PRELIMINARY 1.2. DURING USE 1.3. AFTER USE PRODUCT DESCRIPTION PREPAPATION FOR USE 3.1. SUPPLY VOLTAGE 3.2. CALIBRATION 3.3. STORAGE OPERATION 4.1. PROBE DESCRIPTION 4.2.
  • Página 17 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 1. SAFETY PRECAUTION AND PROCEDURES For your own safety as well as that of the apparatus, must follow procedures described in this instruction manual especially read notes preceded by the symbol carefully.
  • Página 18 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 1.1. PRELIMINARY This apparatus has been designed for illuminance measuring using. Check if the battery is installed correctly. Output Voltage There is a switch inside Select Switch 0.2V this luxmeter for the user to select the full range...
  • Página 19 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 2. PRODUCT DESCRIPTION The luxmeter probes are illuminance to voltage converters. The probes are battery operated and designed to provide direct Luxmeter reading when connected to any high impedance digital multimeter (DMM) that accepts shrouded banana plugs (HT53) and Hypertac connector (HT53/05) and has 1mV DC...
  • Página 20 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 3.3. STORAGE In order to guarantee the accuracy of the measurements, after a period of storage in extreme environment condition, wait for the time necessary so that the apparatus returns to normal measuring conditions (see paragraph 6.2).
  • Página 21 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 4.2. ILLUMINANCE MEASURING WARNING Maximum input voltage is 10 VRMS. Do not attempt to apply any voltage that exceeds limits indicates in this manual avoid electrical shock hazard damage instrument.
  • Página 22 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 5.2. CHECKING THE BATTERY 1. When “LOW BATT” LED indicator light up, Replace battery. 2. The condition of the battery can be checked with a DMM. To do this set the power switch to position OFF, connect the probe to the DMM and set the DMM to voltage scale.
  • Página 23 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 6. TECHNICAL SPECIFICATIONS 6.1. CHARACTERISTICS Accuracy is referred to the following reference conditions: 23°C±5°C with RH<80% 6.1.1. Lux measuring Measurement range: 0.00~20.00lux 0~2000lux 10~20000lux Accuracy: ±(3%RH + 5mV) for CIE standard illuminant A (2856k) Relative visible-spectrum response (f1’): ≤...
  • Página 24 manuals and user guides at all-guides.c HT53 HT53/05 Release EN 1.01 – 19/04/2002 6.1.3. Outputs Signal output: 20lux range 1mV DC per 0.01lux 2000lux range 1mV DC per 1lux 20000lux range 1mV DC per 10lux Output impedance: approx. 500Ω DMM input impedance: 1 Mohm minimum (at 2V scale) Maximum output capability: 4VDC maximum.
  • Página 25 manuals and user guides at all-guides.c ESPAÑOL Manual de instrucciones...
  • Página 26 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 ÍNDICE: PRECAUCIONES Y PROCEDIMIENTOS DE SEGURIDAD 1.1. INTRODUCCIÓN 1.2. DURANTE EL USO 1.3. DESPUÉS DE SU USO DESCRIPCIÓN PREPARACIÓN PARA EL USO 3.1. TENSIÓN DE ALIMENTACIÓN 3.2. CALIBRACIÓN 3.3.
  • Página 27 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 1. PRECAUCIONES Y PROCEDIMIENTOS DE SEGURIDAD Para la seguridad del usuario y del instrumento se recomienda observar escrupulosamente procedimientos descritos en el presente manual y leer cuidadosamente las notas precedidas por el símbolo No someta el instrumento a fuertes vibraciones.
  • Página 28 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 1.1. INTRODUCCIÓN Este instrumento ha sido proyectado para realizar medidas de luminosidad. Asegúrese que la pila este colocada Output Voltage correctamente. Select Switch 0.2V El conmutador le permite al usuario seleccionar el fondo de escala entre los valores 2V y 0.2V.
  • Página 29 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 2. DESCRIPCIÓN Los luxómetros convierten la luminosidad en tensión. Las sondas está alimentadas con pilas y proyectadas para obtener una lectura directa cuando el luxómetro se conecta a un multímetro digital de alta impedancia que lleva conectores banana (HT53) o conectores Hypertac (HT53/05) y tenga una resolución de 1 mVCC y una...
  • Página 30 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 3.3. ALMACENAMIENTO Para garantizar la precisión de las medidas, antes de utilizar el instrumento después de un período de almacenaje en condiciones ambientales extremas, espere que el instrumento vuelve a las condiciones normales de medida (ver párrafo 6.2.1).
  • Página 31 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 4.2. MEDIDAS DE LUMINOSIDAD ATENCIÓN La máxima tensión de entrada es 10 VRMS. No aplique tensiones superiores para evitar riesgos de choques eléctricos daños instrumento. La sonda tiene un conmutador de cuatro posiciones.
  • Página 32 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 5.2. CONTROL DE LA PILA 1. Reemplace la pila cuando se encienda el LED “LOW BATT." 2. El estado de la pila puede ser controlado con un multímetro. Para comprobarlo, posicione el conmutador OFF, conecte...
  • Página 33 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 6. ESPECÍFICACIONES TÉCNICAS 6.1. CARACTERÍSTICAS La precisión se refiere a las siguientes condiciones: 23°C ±5°C con HR < 80% 6.1.1. Medida de lux Campo de medida: 0.00~20.00 lux 0~2.000 lux 10~20.000 lux Precisión:...
  • Página 34 manuals and user guides at all-guides.c HT53 HT53/05 Versión SP 1.01 – 19/04/2002 6.1.3. Salidas Rango 20lux 1mVDC por 0.01lux Rango 2000lux 1mVDC por 1lux Rango 20000lux 1mVDC por 10lux Impedancia de salida: aprox. 500Ω Impedancia de entrada del multímetro: mínimo 1 Mohm (a 2V) Máxima capacidad de salida: 4VCC...
  • Página 35 manuals and user guides at all-guides.c...
  • Página 36 Via Righi 126 48018 – Faenza (RA) – Italy Tel: +39-0546 621002 (4Linee r.a.) Fax: +39-0546-621144 Email: ht@htitalia.it http://www.htitalia.com...