IF CONTROL VALVE 4 IS COMPLETELY CLOSED,
THE WATER PUMP WILL CUT OUT. TO RESTART IT,
CONTROL VALVE 4 NEEDS TO BE OPENED
SLIGHTLY.
D
RAINING THE WATER
The tank has a drain plug so that it can be thoroughly emptied
when the operating cycle has been completed.
Warning
To prevent the formation and growth of bacteria and
other
pathogenic
salmonella, do not leave water in the tank for
extended periods of time.
Therefore all water remaining inside must be drained
at least once a week by opening the cock at the
bottom of the tank.
MAINTENANCE
Warning
Before performing any maintenance:
• stop the humidifier;
• switch off the power supply by means of the
disconnector on the electrical panel;
• wait until the humidifier has cooled down.
For the humidifier to operate efficiently, it must be cleaned
regularly. An accumulation of dust and dirt can reduce performance.
In addition, the amount of water reaching the centrifuge must be
periodically checked to ensure that it is correct; if necessary, adjust
the flow regulator. Keep discs, tank and internal components clean;
do not allow dirt to accumulate on the lid.
C
LEANING THE DISC
Keep the disc clean to prevent the formation of scale or an
accumulation of dirt that could increase vibrations or produce
a coarse spray.
To clean the rotating disc, simply use a soft cloth dampened
with a non-toxic, solvent-free cleaner, wiping carefully without
applying excessive pressure.
Do not use solvents.
The fixed disc should be cleaned with a small, stiff-bristled
brush, carefully cleaning the teeth to prevent damage.
L-L305.00-BM
microorganisms
such
as
EN
Any scale can be removed with muriatic acid diluted with
water.
C
LEANING THE TANK
Clean the tank periodically.
To gain access, loosen the two screws on the cover and pull
gently on the hook.
Once these steps have been completed, the inside of the tank
can be cleaned with a cloth or sponge, gently rubbing down
the walls. Do not use solvents.
O
PERATIONS AT BEGINNING
Operations at beginning/end of season:
empty the tank completely by opening the cock at the bottom,
wash the inside of the tank with a 5% aqueous solution of
sodium hypochlorite (bleach),
rinse thoroughly with clean water,
finally empty out the tank to remove all solution and dirt
residues,
at the end of the season, leave the tank empty.
at the beginning of the season, before filling the tank with
clean water, rinse it out with clean water at least once to
ensure there has been no build-up of dirt or material that may
be hazardous to one's health..
DISPOSAL
At the end of its working life, this machine is to be scrapped and
disposed of by handing it over to the local separate waste collection
system pursuant to and in scrupulous compliance with current
legislation.
Before scrapping, check the machine's serial number label. If the
label bears this symbol
by Legislative Decree no. 151 of 25/07/2005 and directive
2003/96/EC on Waste Electrical and Electronic Equipment (WAEE).
You should therefore become apprised of the local waste
collection system for electrical and electronic products and comply
with its requirements.
Improperly disposing of this product as normal municipal waste
may result in serious harm to the environment and human health and
may be subject to penalties from local authorities.
/
END OF SEASON