Descargar Imprimir esta página

ZAPTEC Go Manual De Instalación página 16

Ocultar thumbs Ver también para Go:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 222
English
10. Install multiple chargers (continued)
3 phase installation
Maximum total current 32A
3 phase for the chargers
40A
40A
40A
Circuit breaker and RCD
type A.
Must be equal in value
on installations with
several Zaptec Go.
One circuit breaker
and RCD Type A per
Zaptec Go.
N, L1, L2. L3
N, L3, L1. L2
N, L2, L3. L1
Phase rotation for
better load distribution
during 1 phase charging.
Integrated residual current
protection RDC-DD (6mA DC)
according to IEC 62955
When rotating phases on a 3-phase installation, you must use the Zaptec app
to specify which incoming phase (L1, L2 or L3) is connected to the phase 1 terminal
on the charger. This can only be done via the Install Zaptec Go journey in the Zaptec app.
16

Publicidad

loading