Contents
Warning ....................................................................................................
Characteristics .......................................................................................
Symbol, Connection, Description ...................................................
Technical parameters ..........................................................................
Light sensor, Control description ..................................................
Mode precedence, Language settings .........................................
Menu overview ......................................................................................
Light functions setting .......................................................................
Date and time setting .........................................................................
Time program ........................................................................................
Setting the switching modes ...........................................................
Setting options ......................................................................................
Deleting of all programs, Reset .......................................................
An example of programming .........................................................
2
Warning
2
Device is constructed for connection in 1-phase main alternating current
voltage 230 V and must be installed according to norms valid in the state
3
of application. Connection according to the details in this direction.
Installation, connection, setting and servicing
should be installed
4
by qualifi ed electrician staff only, who has learnt these instruction
6
and functions of the device. This device contains protection against
overvoltage peaks and disturbancies in supply. For correct function
7
of the protection of this device there must be suitable protections of
8
higher degree (A, B, C) installed in front of them. According to standards
elimination of disturbancies must be ensured. Before installation the main
9
switch must be in position "OFF" and the device should be de-energized.
10
Don´t
install the device to sources of excessive electro-magnetic
interference. By correct installation ensure ideal air circulation so in case
12
of permanent operation and higher ambient temperature the maximal
operating temperature of the device is not exceeded. For installation
14
and setting use screw-driver cca 2 mm. The device is fully-electronic -
18
installation should be carried out according to this fact. Non-problematic
function depends also on the way of transportation, storing and handling.
20
In case of any signs of destruction, deformation, non-function or missing
21
part, don´t install and claim at your seller it is possible to dismount the
device after its lifetime, recycle, or store in protective dump.
22
Characteristics
Ex9LDS 2CO 230V features a sundown switch and digital time
switch clock with weekly and annual program. Thanks to this
combination, you can control lighting based on the ambient
light level while changing in real time the lighting intensity tog-
gle range and „lock" the output when the light doesn't need to
be on. This lets you achieve the required eff ect (where all night
lighting is not necessary - advertisement, parking areas, walk-
ways) and save on both energy and lamps.
- used to control lighting based on ambient light intensity, on
real time and the on the time control switch
- the advantage of real time is blocking the sundown switch
function when illuminating seems ineffi cient (night time,
weekends, etc.)
- adjustable light intensity level 10-50,000 lux
- when no one's around, the random switching function simu-
lates the presence of persons
- external sensor with IP44 rating for mounting on the wall / in a
panel (cover and sensor holder are a part of the supply)
- Switching modes:
- Auto – automatic switching mode:
- Programme
– switches according to program (light func-
tions or time program).
- Random
– switches randomly in a 10–120 minute interval.
- Holiday
– holiday mode – option of setting up a period for
which the timer will be blocked, i.e. will not switch based on
the set programmes.
- Manual
– manual mode – option of controlling the individ-
ual output relays manually
- Options for automatic switching program:
- lights - switching according to set light intensity range
- time program - switches according to set time program
- 100 memory locations for time programs.
- Each memory position can switch on/off the relay or set the
lighting intensity toggle range according to lux value.
- Programming can be performed under voltage and in backup
mode.
- The relay outputs do not work in backup mode (battery-powered)
- Choice of menu display - CZ / SK / EN / ES / PL / HU / RU (factory
setting EN).
- Choice of automatic daylight savings time transition according
to time zone.
- Backlit LCD display.
- Easy and quick setting with the help of 4 control buttons.
- Pluggable transparent cover on front panel.
- The time switch clock has a battery backup, which retains data
in case of a power outage (reserve backup time - up to 3 years).
- Power supply: 230V
- 2-module, DIN rail mounted