Wear ear protection.
WARNING:
WARNING:
The noise emission during actual
use of the power tool can differ from the declared
value(s) depending on the ways in which the
tool is used especially what kind of workpiece is
processed.
Be sure to identify safety mea-
WARNING:
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
Vibration
The following table shows the vibration total value
(tri-axial vector sum) determined according to applica-
ble standard.
Model HR3011FC
Work mode
Vibration
emission
2
Hammer
10.8 m/s
drilling into
2
9.0 m/s
concrete
(a
)
h, HD
2
Hammer
10.4 m/s
drilling into
2
8.1 m/s
concrete with
DX10 (a
)
h, HD
2
Chiselling
9.7 m/s
(a
)
h, CHeq
2
9.9 m/s
Model HR3012FC
Work mode
Vibration
emission
2
Hammer
10.5 m/s
drilling into
2
8.7 m/s
concrete
(a
)
h, HD
2
Hammer
10.0 m/s
drilling into
2
8.1 m/s
concrete with
DX11 (a
)
h, HD
2
Chiselling
8.2 m/s
(a
)
h, CHeq
2
7.5 m/s
Uncertainty (K) Applicable
standard /
Test condition
2
1.5 m/s
EN62841-2-6
2
1.6 m/s
Recommended
practical
operation*
2
1.5 m/s
EN62841-2-6
2
1.5 m/s
Recommended
practical
operation*
2
1.5 m/s
EN62841-2-6
2
1.5 m/s
Recommended
practical
operation*
Uncertainty (K) Applicable
standard /
Test condition
2
1.5 m/s
EN62841-2-6
2
1.5 m/s
Recommended
practical
operation*
2
1.5 m/s
EN62841-2-6
2
1.5 m/s
Recommended
practical
operation*
2
1.5 m/s
EN62841-2-6
2
1.6 m/s
Recommended
practical
operation*
Model HR3001C
Work mode
Vibration
emission
Hammer
12.2 m/s
drilling into
17.3 m/s
concrete
(a
)
h, HD
Chiselling
10.4 m/s
(a
)
h, CHeq
12.4 m/s
* The test condition of recommended practical operation
meets EN 62841-2-6, except for the following points:
•
Feed force is applied to the switch handle (main
handle) for working accuracy and efficiency.
•
The side grip/handle (auxiliary handle) is held to
keep balance of the tool.
NOTE: The declared vibration total value(s) has been
measured in accordance with a standard test method
and may be used for comparing one tool with another.
NOTE: The declared vibration total value(s) may also
be used in a preliminary assessment of exposure.
WARNING:
actual use of the power tool can differ from the
declared value(s) depending on the ways in which
the tool is used especially what kind of workpiece
is processed.
WARNING:
sures to protect the operator that are based on an
estimation of exposure in the actual conditions of
use (taking account of all parts of the operating
cycle such as the times when the tool is switched
off and when it is running idle in addition to the
trigger time).
EC Declaration of Conformity
For European countries only
The EC declaration of conformity is included as Annex A
to this instruction manual.
SAFETY WARNINGS
General power tool safety warnings
WARNING:
tions, illustrations and specifications provided
with this power tool. Failure to follow all instructions
listed below may result in electric shock, fire and/or
serious injury.
Save all warnings and instruc-
tions for future reference.
The term "power tool" in the warnings refers to your
mains-operated (corded) power tool or battery-operated
(cordless) power tool.
10 ENGLISH
Uncertainty (K) Applicable
2
2
1.5 m/s
2
2
1.5 m/s
2
2
1.5 m/s
2
2
1.5 m/s
The vibration emission during
Be sure to identify safety mea-
Read all safety warnings, instruc-
standard /
Test condition
EN62841-2-6
Recommended
practical
operation*
EN62841-2-6
Recommended
practical
operation*