Attention: Minimum Calibration functionality.
The Twinmaster is factory adjusted to be able to work properly with the most common fans.
Nevertheless, it is still possible to adjust the minimum speed to your own ventilation of choice. A
software setting was included for this.
The software-based Minimum Calibration function works as follows.
1. Make sure the device is disconnected from the power supply.
2. Turn the 3 buttons so the lines are facing up
Effectively, the 3 buttons are in the middle of their range,
(1)
(2)
so left button
40%, middle button
27 degrees,
(3)
right button
80%.Connect the device to mains power.
3. The ventilation will now run at maximum speed for a few seconds before returning to the set
minimum factory setting.
(1)
4. The left button
allows the user to further adjust the minimum speed. Left of the middle, the
ventilation will run slower than the factory setting, and to the right of the middle, the ventilation will
run faster than the factory setting.
5. When the desired speed has been set, turn the button to the right
100%. The fan/fans will now run at full speed briefly, and then return to normal functionality. This is
the sign that the new setting has been saved.
6. The device can now be configured according to your requirements (min/temp/max).
Turn down the speed in such a manner that the fan/fans always keep running.
(see image)
(3)
to the maximum setting,
Usermanual
Technical Specifications
Twinmaster 7Amp
Adjustable capacity
Max. 7Amp
Input
230v-240v 1Ph
50Hz
Frequency
Dynamic range
0.5 - 7.0Amp
Temp. sensor (Ntc 5 meters)
4K7 at 25˚C
Twinmaster 14Amp
Adjustable capacity
Max. 14Amp
Input
230v-240v 1Ph
Frequency
50Hz
Dynamic range
0.5 - 14.0Amp
4K7 at 25˚C
Temp. sensor (Ntc 5 meters)
Twinmaster
7/14Amp
5 YEAR Warranty
The Twinmaster product warranty(terms & conditions),
excludes faulty fuses. The manufacturer shall not be
responsible for any damage caused by operation of
the unit, be it incidental or consequential; or of any
type; including, without limitation, damage or injury,
caused to other products, machinery, or buildings.
Nor will responsibility be accepted for loss of time or
profit, loss of finished products, or for any inconven-
ience caused in any way whatsoever.
Disposal
This unit is not suitable for disposal as or with house-
hold waste. It should be taken to a local recycling
centre.
Have the Twinmaster connected by a
recognized installer.