The KMINA Toilet Frame has been designed to provide additional support for toilet functions, preventing
accidental slips or falls. Thanks to its height, width and depth adjustments, it adapts to any toilet and user. It
has been designed to be used by the elderly, pregnant women and/or people with mobility difficulties.
1. PRODUCT PARTS
1. Armrests.
2. Adjustment button.
3. Height adjustment.
4. Inner tube.
5. Lateral suction pad.
6. Rubber centering.
7. Horizontal tube.
8. Width adjustment.
2. ADJUST
1. Lift the armrest (A) to the desired position, insert the adjusting thread (C) into the hole and rotate it
clockwise until it is securely fixed to the tube. Then insert the lateral suction pad (D) into the inner tube. Follow
the same steps to mount the other armrest.
2. Insert the armrests to the horizontal tube (E) and fix them with the height adjustment threads (F). The
horizontal tube (E) can be adjusted in two angles (0º/45º) and in two positions with different width (27"/30").
3. Place the device with the horizontal tube fully leaned on the front of the toilet.
4. Adjust the lateral suction pads on both sides of the toilet. Make sure both are completely fixed. The thread
should be above the yellow line to ensure proper hold. The two armrests must be parallel to the floor.
5. Find the center line and confirm that it is at least 15" away from the walls on both sides.
3. USE
1. This device is designed to provide additional support and stability for toilet functions.
2. Use the adjustment buttons under the armrest for more comfortable support.
3. Before use, shake the armrests with your hands to check their stability.
WARNINGS
- Read instructions before installation.
- All threads should be fasten and tighten. Suction pads must be tighten securely to the toilet.
- Do not disassemble, repair, or modify any component.
- Users with limited physical capabilities should be supervised or assisted when using the device.
- This device is not designed to support the total weight of an individual. The weight limit for the user is
330 lb. Do not stand on this product. Do not use as a lifting aid.
- The armrests are intended to be used on both sides evenly. If pressure is applied on one side only, use only
half of the body weight. At overload, there is a risk that the armrest will break.
- Check that all components and parts are properly assembled and bolted together before use.
- Keep away from heat.
- Any serious incident related to the product should be reported to the manufacturer and the competent
authority of the Member State in which they are user and patient set.
CLEANING AND MAINTENANCE
- Clean regularly by hand with a damp cloth, do not use abrasive products for cleaning or rinse with water.
- Disinfect the product by cleaning all accessible surfaces with disinfectant (after disassembly, if possible). All
cleaning products used must be effective, compatible with each other and protect the materials to be cleaned.
- For disinfection in hospital environments, follow the instructions of a hygiene specialist.
MAINTENANCE AND PERIODIC INSPECTION
The product is maintenance-free, provided the cleaning and safety instructions outlined above are adhered to.
Check product regularly for damage and to ensure that it is securely assembled.
COD E
KM I NA TOI LE T FR AM E
K 30001