Descargar Imprimir esta página

GAF EZCool EZCG1 Instrucciones página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Figure 3a
T-STAT
Note: See Figures on previous page.
1 . Ensure Proper Intake Ventilation. Always ensure
there is proper intake ventilation at or near the
soffit. This is required for a balanced ventilation
system and to help avoid premature ventilator motor
failure. Use the chart located on the outside of the
package or visit gaf.com/ventcalculator to ensure
the minimum recommended intake ventilation is
installed on the home. Always consult local building
codes for ventilation requirements.
2. Position the Vent. Place the ventilator behind an
existing gable wall louver or install a Master Flow
SGM2O Automatic Gable Louver (not included).
The fan should be approximately 3" (76 mm) to
4" (102 mm) away from the exterior louver.
3. Attach Mounting Brackets to Unit. Carefully remove
unit and mounting accessories kit from the carton.
The fan mounting kit includes (8) bolts, (8) Nylok
nuts, and (4) mounting brackets. Take the mounting
brackets (long side) and align with the two holes on
the shroud. With holes aligned, take two bolts with
the head on the inside of the shroud and push
through each hole. Take the Nylok
to each bolt. Repeat this process until all four
mounting brackets are firmly fastened to shroud
(Figures 1a & 1b).
gaf.com
4. Mount the Unit. Place mounting brackets so end
is flush with the stud. For studs 16" (406 mm) on
center, mounting brackets are predrilled to this size.
Screw or nail unit to framing through pre-punched
holes in mounting brackets (Figure 2a). For studs
over 16" (406 mm) on center, install two nominal 2"
x 4" (50 mm x 100 mm) wood supports, 14" (356
mm) apart. Mount the unit to the two nominal 2" x 4"
(50 mm x 100 mm) wood supports through the pre-
punched holes in the mounting brackets (Figure 2b).
5. Mount the Thermostat. Remove the thermostat
cover and mount the thermostat box to the edge of
®
an adjacent rafter or stud pre-punched holes in the
box. Always leave some slack in the flexible conduit
and ensure the thermostat element in the back of
the box is NOT covered. Each ventilator must have
its own thermostat.
NOTE: Select models include an optional combination
humidistat/thermostat control.
6. Connect to Power Source. For plug-in, see section
6a. Alternatively, if you would like to hardwire your
ventilator or are required to do so by local building
nuts and fasten
and/or electrical code, see section 6b.
INSTRUCTIONS
Gable Mount Model: EZCG1
Figure 3b
POWER SOURCE
NEUTRAL (WHITE)
GROUND (GREEN)
HOT (BLACK)
BLACK
T-STAT
6a. Plug-In. Plug the fan into a 110v grounded
receptacle as shown in figure 3a.
WARNING: Fan may start immediately if temperature
and/or humidity (select models) conditions are met.
Refer to "Ventilator Settings" in section 7.
6b. Optional Hard Wire: Always disconnect power
supply before wiring the ventilator into an existing
grounded circuit. Remove the thermostat cover
and disconnect the EZ plug cord. Then remove the
EZ plug cord from the thermostat box. Wire the
thermostat as shown in figure 3b and replace the
thermostat cover.
7. Ventilator Settings. The included thermostat is
adjustable from 6O°F (15.5°C) to 12O°F (48.8°C).
The factory-set/recommended setting for efficient
operation is 105°F (40.5°C). For select models
with humidistat/thermostat control, the humidity
should be set at 70%.
Note: In the unlikely event accessories or parts are
missing or this product does not operate correctly,
please contact Master Flow
l-8OO-211-9612 or email WarrantyLLBP@gaf.com.
Do NOT return this ventilator to retailers or distributors.
We protect what matters mos t
WHITE
MOTOR
GREEN
BLACK
BLACK
Technical Services at
®

Publicidad