Orbis ORUS RF Manual Del Usuario página 53

Cronotermostato digital por radiofrecuencia
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SETTING/TEST OF REMOTE ACTUATOR
The remote actuator activates the load after a radio frequency signal sent by the
programmable thermostat ORUS RF.
Operation
• For details about the functional characteristics of the remore actuator, refer to the
documentation supplied with the instrument.
Channel setting
• Activate setting mode ad described in the documentation of the remote actuator.
• When the setting mode is active the actuator must receive a configuration string.
• After string reception the channel is set and the actuator starts the normal operation.
• For re-setting the channel, repeat this procedure. Every new setting resets the previous
one.
ORUS RF setting
• The field (22) displays "oUt="; the field
(16) displays "CnF" flashing.
• Verify that the remote actuator is in setting
mode.
• Press the "PRG" key for almost 3 seconds.
When the setting is completed, on the field
"24" the symbol "
the page of radio communication test is
displayed.
TEST COMMUNICATION
• During the test, field (22) displays "oUt=",
field (16) displays "tSt" flashing and field
(15) displays "ON" or "OFF" to indicate if
the test is activated or not.
• To activate the test press for some seconds
the key "PRG".
• If the modality-test is actived, the display
shows "
" when the relay is in position
ON, while the absence of this symbols
indicates that the relay is OFF. The switching
" appears and then
- 51 -
ORUS RF Programmable Thermostat User Manual

Publicidad

Tabla de contenido
loading

Tabla de contenido