7.1
TPS Theft Protection System (optional)
The product can be equipped with the optional TPS theft protection system. If the product you own
is equipped with this function it can be unlocked and made ready for operation only though use of the
corresponding TPS key.
Enabling product
▶ Make sure that the product is connected to the electricity supply. The yellow theft protection indicator
flashes. The product is now ready to receive the signal from the TPS key.
▶ Hold the TPS key or the TPS watch strap buckle against the lock symbol. As soon as the yellow theft
protection indicator goes out, the product is enabled.
If, for example, the electric supply is briefly interrupted due to a power failure or disconnected
when moving to a different workplace, the product remains ready for operation for approx. 20
minutes. In the event of a longer interruption, the TPS key must be used again to unlock the theft
protection system.
Further detailed information on activation and use of the theft protection system can be found in
the operating instructions for the TPS theft protection system.
7.2
Use of the two-part hole-starting aid
CAUTION
Risk of injury caused by incorrect use! Parts can come off the hole-starting aid if it is not pressed against
the work surface.
▶ When a two-part hole-starting aid is used, do not run the diamond core drilling machine without the
hole-starting aid pressed against the work surface.
A different hole-starting aid is required for each core bit diameter.
1. Fit the hole-starting aid into the open end of the diamond core bit.
2. When you start drilling apply only light pressure until the core bit has centered itself. Then apply more
pressure. Drill a guide cut 3-5 mm deep.
3. Release the on/off switch to stop the product. Wait until the core bit comes to a complete stop.
4. Remove the hole-starting aid from the core bit.
5. Position the core bit in the guide cut, press the on/off switch and resume drilling.
7.3
Operating portable residual current device (PRCD)
WARNING
Risk of injury due to electric shock! Do not continue operating the diamond core drilling machine if the
indicator on the ground fault circuit interrupter does not go out when the 0 or the TEST button is pressed.
▶ Have your diamond core drilling machine repaired by Hilti Service.
1. Plug the diamond core drilling machine's mains plug into an earthed/grounded power outlet.
2. Press the "I" or "RESET" button on the portable residual current device (PRCD).
▶ The indicator lights up.
3. Press the "0" or "TEST" button on the portable residual current device (PRCD).
▶ The indicator goes out.
4. Press the "I" or "RESET" button on the portable residual current device (PRCD).
▶ The indicator lights up.
7.4
Dry-drilling with dust removal
Allowing dust to build up in quantity inside the core bit can cause imbalance.
When working, always route the suction hose to the rear and away from the diamond core drilling
machine, so that it cannot come into contact with the core bit.
24
English
274860