Trouble shooting
Problem
Device does not start
Low or lack of suction
Float does not switch
the appliance off
Dust or dirt is blow
out of the device
22
Possible cause
Mains voltage is not pres-
ent
Defective on/off switch
(
3)
Worn carbon brushes
Defective motor
Hose system (
(
20/21) blocked
Suction pipe (
sembled incorrectly
Container (
8) open
Container (
8) full
Filter (
17/18/19) full or
clogged
Float in filter basket (
incorrectly positioned (e.g.
due to jerky movements)
Float in the filter basket
(
22) faulty
Float in the filter basket
(
22) does not move
Float in the filter basket
(
22) faulty
Filter (
17/18/19) is not or
not correctly assembled
Fault correction
Check plug socket, cable, line,
plug and fuse, where appropri-
ate, repair through electrical
specialist
Repair through customer ser-
vice
Remove obstructions and block-
15) or jets
ages
14) as-
Assemble suction pipe correctly
Close container
Empty container
Empty, clean or replace filter
22)
Switch off the equipment so the
ball drops then switch on again
Repair by Customer Care
Release float
Repair by Customer Care
Use missing filters or check the
correct position of the filter

Publicidad