Option 2 - 230 V single-phase with neutral
conductor
230 V
230 V
Option 3 - 230 V single-phase without neutral
230 V
With this configuration (without a neutral conductor
and with 230 V from line to line), any two lines (L1, L2
or L3) from the mains are connected to terminals L1
and N on the charging station's terminal strip.
Terminals L2 and L3 must not be used.
Option 4 - 230 V three-phase without neutral
230 V
230 V
230 V
With this configuration (without a neutral conductor
and with 230 V from line to line), you connect two lines
(L1 and L2) to terminals L1 and L2 on the terminal strip.
Connect line L3 to neutral on the terminal strip.
This option is not compatible with all vehicles.
L1
L2
L3
N
PE / G
M+P-03F-9924
Preparing the Internet connection
So that you can use all the functions available with the
wallbox, the device requires an Internet connection.
The wallbox can be connected to the Internet using the
following options:
L1
•
•
L2
•
Optional: Connecting a network cable (RJ45)
L3
N
PE / G
M+P-03F-9923
L1
L2
L3
N
PE / G
M+P-03F-9922
- 13 -
Connect mains cable (19) to the wallbox in a
manner appropriate for the existing power supply.
Note that lines that are single-insulated only must
not touch the motherboard of the wallbox. If this
cannot be ensured, provide additional insulation
for these lines.
Check that connected cables are firmly seated.
Fasten the cable strain relief device for the cable
duct in place by hand.
Wi-Fi connection
Connecting a network cable (RJ45)
SIM card
Insert the network cable in the wallbox from
underneath through the left cable duct and
connect it.
M+P-03F-9936