4
D
HPR PAC
Dry Cutting System
C
041993
S101
J106
J107
CONTROL
ON
1
2
1
2
BOARD
S100
1 2 3 4
J303
ON
1 2
3 4
1
2
3
4
1 2 3 4 5 6 7 8
Serial ID
Machine Motion
Dipswitch
Jumper Block
J300A
J300B
B
CNC Interface Cable
Dipswitch setting example:
S100
ON
1
2
3
4
5
6
7
8
A
Switch 1 is in the On position
Switches 2-8 are in the Off position
4
3
Optional Remote On/Off
TB2
RED/BLK
RED/BLK
RED
RED
WHT
Gas Power Cable
RED
WHT
RED
Remote On/Off
Customer Supplied
3
NUMERIK SRL - www.pantografosnumerik.com.ar
2
Notes:
1) For single system installation set Serial ID (S100), Machine
Motion (J303), J106 & J107 as shown.
Relocate the white wire on TB2 from position #3 to position
#2. Connect customer supplied Remote On/Off cable in series
with the power supply and the gas console power switch.
Connect one terminal of the Remote On/Off cable to position
#2 on TB2 and the other terminal to position #3.
Refer to page 3 of the wiring diagram
Depress the Gas Console Power switch to the closed position (on position).
2) For a multi-system installation set up as described above, set jumpers as shown on the
multi-system interface page
3) The CNC will need a dedicated I/O for each system using the Remote On/Off feature
(contact should be rated for min. 24Vac, 0.5 Amp)
* If a Hypertherm Automation controller is being used, and there are intermittent communication
failures (PS Link Failure), try removing the jumnpers on J104 and J105 on the control board, and the
termination jumper (J6 or J8) on the serial isolation board in the controler. Only remove
the termination jumper on the serial isolation board that is connected to the HPR
power supply. See figure below for details.
078170
Gas Console
J2
BTR
J7
CNC
Interface
(Customer Supplied)
Serial isolation board in a Hypertherm Automation controller
2
1
J1
SV
BMD
AMD
J3
BHST
AHST
J5
J6
RS-232
RS-232
ATR
J9
J10
J8
RS-422
RS-422
ELEC SCH:HPR260XD POWER SUPPLY
013377
SHEET 17 OF 19
1
D
C
B
A
E
7-21