Descargar Imprimir esta página

Frigidaire FCFE3083SS Instrucciones De Instalación página 6

Publicidad

Idiomas disponibles

Idiomas disponibles

30" ELECTRIC FRONT CONTROL FREESTANDING INSTALLATION INSTRUCTIONS
4-Wire Power Cord Connection
(New branch-circuit or mobile home)
1. Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block.
IMPORTANT NOTE: DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these nuts are
loosened or removed.
2. You must disconnect the ground strap. Remove the
factory installed ground screw and plate to release the
copper ground strap from the frame of the appliance.
Cut and discard the copper ground strap and plate.
Keep the ground screw.
3. Connect the GREEN ground wire lead with the eyelet
to the frame of the appliance with the ground screw
using the same hole in the frame where the ground
screw was originally installed.
4. Follow the manufacturer's installation instructions
supplied with the strain relief and install.
5. Make sure all screws are tightened securely and
replace the rear access cover.
GREEN
4
Remove ground strap
NOTE: Internal white wire not present on all models.
L1
NEUTRAL
L2
RED
Fig. 14
3-Wire Power Cord Connection
(Existing installations ONLY)
A ground strap is installed on this range which connects
the center terminal of the terminal block (Neutral) to the
range chassis. The ground strap is connected to the range
by the center screw (see Fig. 15). The ground strap must
not be removed unless National, State or Local Codes do
not permit use of a ground strap.
NOTE: If the ground strap is removed for any reason, a
separate ground wire must be connected to the separate
ground screw attached to the range chassis and to an
adequate ground source.
1. Insert the end connectors for Line 1, Line 2 and
Neutral and tighten securely to the terminal block.
IMPORTANT NOTE: DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss
of electrical connection may occur if these 3 nuts are
loosened or removed.
2. Follow the manufacturer's installation instructions
supplied with the strain relief and install.
3. Make sure all connections are tightened securely and
replace the rear access cover.
3
Ground screw
NOTE: Internal white wire not present on all models.
6
L1
Ground
strap
NEUTRAL
and plate
L2
RED
Fig. 15

Publicidad