13. USE SUBMERGED PUMPS
The OIL series machines equipped with the submerged pump are fixed with two floats.
The first stops the engines once the maximum level is reached. The motors restart automatically when the
control float is lowered.
The second operates the pump allowing the drum to be emptied.
If the pump is replaced, correctly fix both floats to the bracket provided, keeping the dimensions shown on
the drawing.
MOTOR
PUMP
14. PROTECTION FILTER REPLACEMENT
1. Unhook and lift the head.
2. Loosen the lace.
3. Remove the nylon filter.
4. Replace or clean the protective filter.
5. Insert the filter into the chamber by pulling out the edge with the lace.
6. Knot the lace and then place the head on the chamber.