COMPONENTS
CONTROL PANEL COMPONENTS
1. Fuel Selector Switch: Used to select gas or propane
operation.
2. Run/Stop Switch: Push to Run position to start or
Stop position to shut the generator off.
3. Main Circuit Breaker: The main circuit breaker
controls total output of all outlets to protect the
generator from overload or short circuit.
4. Voltage Selector Switch: Select 120V or 240V. Turn
generator OFF before switching voltage. When
operating at 240V only the L14-30R receptacle is
operational.
5. 120/240 Volt AC, 30 Amp NEMA L14-30R Twist-
Lock Receptacle: Receptacle can supply a
maximum of 30 Amps
6. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle:
Receptacle can supply a maximum of 30 Amps.
7. 120 Volt AC, 20 Amp Duplex NEMA 5-20R
Receptacles: Receptacles can supply a maximum of
20 Amps.
All manuals and user guides at all-guides.com
8.
9.
10. Ground Terminal: The ground terminal is used to
COMPONENTS
20 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the NEMA
5-20R receptacles to 20 Amps.
30 Amp AC Circuit Breaker: Circuit breaker limits
the current that can be delivered through the TT-
30R receptacle to 30 Amps.
externally ground the generator.
11. CO Sensor indicator lights: The CO Sensor
monitors for the accumulation of poisonous carbon
monoxide gas. If increasing levels of CO gas are
detected, the CO Sensor automatically shuts down
the engine
Westinghouse Outdoor Power Equipment, LLC | 11