Initial inspection
Before installing the electrical relay switch,
ensure that all parts are included in the package.
If any part is missing or damaged, do not
attempt to install, or operate this product.
Estimated installation time: 10 minutes.
Tools that may be required but are not
included for installation
1
Phillips screwdriver
2
Flathead screwdriver
3
Wire strippers/cutters
Hardware installation
Step 1
Cut in half the xture or device cable that you wish to
connect to the smart relay switch. Strip the cable's jacket
to to leave the wires bare and facilitate the connection to
the relay terminals.
Step 2
Remove the terminal screw covers. On the output side,
attach the wires coming from the xture or device to the L
(Live) and N (Neutral) terminals on the relay switch.
Proceed to tighten the terminal screws to make sure the
connection is secure.
Step 3
Repeat the same procedure on the input side of the relay
switch, but this time connecting the two electric wires
from the grid. Make sure to match the N (Neutral) wire
with Neutral terminal on the input section of the relay. Do
the same with the L (Live) wire. Avoid accidentally
reversing the wires to prevent malfunction or damaging
the device.
Input connection
N
L
Output for load