DISPLAY
PARAMETERS
MAXIMUM
HF 50
FREQUENCY
SWITCHING
FS 8
FREQUENCY OF
MODULE
LOW PRESSURE
LP 0,2
ALARM THRESHOLD
FLOW SENSOR
FWS 0
SECOND PRESSURE
2P 2.5
OF SET
RESETTING
SET.F
OF FACTORY
PARAMETERS
40
| ENGLISH
DESCRIPTION
Sets the maximum operating frequency.
ATTENTION: the increase in the maximum
frequency.
compared to the nominal frequency can
cause strong overloads of the motor.
Sets the switching frequency of the power
module.
Sets the alarm threshold for too low an
operating pressure (possibility of a broken
tube).
Sets the presence/absence of the flow
sensor:
0 = sensor not present.
1 = flow sensor present.
Sets a second value for the system pressure
(constant). To activate it configure the
parameter EI in the advanced parameters.
Press the ENTER key until "OK" appears on the display, all the parameters return to
their factory settings.
u.m. Default Min
Max
MF
MF
Hz
MF
-10
+5
kHz
8
4
10
bar
0,2
0
10
-
0
0
1
bar
2,5
1
9
psi
50
15
130
Step
1
2
0,1
1
0,1
1,5