OPERATION MANUAL AND INSTRUCTIONS
• Place the angle indicator on the tool and quickly press button (S/S) to start tightening. The angle indicator is fitted with a magnet,
to provide perfect stability (picture 2-o).
• When 80% of the selected angle is reached, the first green LED will turn on and the buzzer will sound.
• When the set angle value is reached, the red LED will turn on.
• To store the value of the torque angle, press button M.
CAUTION: If the tightening process is interrupted for a few seconds, the display will blink, confirming that the required angle has
been reached. To resume tightening, press button (S/S). To zero the device, press button C.
• To start a new tightening operation, press button S/S.
If the display is not used for approximately 2 minutes, it will automatically turn off.
SETTING UP MENU
Keep button S/S pressed to enter the configuration menu. Press button S/S several times to enter the menus: CHANGING
TORQUE DIRECTION, TORQUE MEMORIES AND RESETTING TORQUE MEMORIES.
CHANGING TORQUE DIRECTION MENU
- The display will show PoS for the clockwise direction of rotation, and nEG for the anticlockwise direction
of rotation respectively.
- Press buttons ▲and ▼to change the direction of rotation.
- To quit the menu, press button (S/S) several times.
TORQUE MEMORIES MENU
- This menu provides the values of the measured and stored torque angles (up to 50 values stored).
- If no values have been stored, the display will show nonE.
- Whenever buttons ▲and ▼are pressed, the display will show the stored values of the torque angle.
- To delete one of the stored values, press button C twice.
- To quit the menu, press button (S/S) several times.
RESETTING TORQUE MEMORIES MENU
- This menu allows all the values stored in the TORQUE MEMORIES MENU to be deleted.
- The display will show ClrA
- To delete all the stored values, press button C.
- The display will show no?
- To delete all the stored values, press button C. To cancel the operation, press button S/S.
- To quit the menu, press button S/S twice.
ERROR MESSAGES
- Er4 indicates that the value has not been set correctly. Press button C to repeat the operation. Do not move the
angle indicator while setting.
- Er5 indicates that the angle indicator is not working correctly. Press the RESET button.
- Er--- indicates that the angle indicator was rotated too quickly during a measurement. Press button C to repeat the
operation.
- Full indicates that no data can be stored in the memory; the memory is full. Delete some of the 50 stored data.
RESET
- If the angle indicator is not working correctly, press the RESET button to zero the device (picture 2-r). The angle
indicator can also be zeroed by removing the batteries.
EN
9