_________________________________________________________________________ use and instruction manual
3. Technical specifications
Dimensions of appliance LxDxH (mm)
Weight (Kg)
Maximum load per tray: GN1/1-600x400mm (kg)
Maximum load: GN1/1-600x400mm (kg)
Convection heating element (kW)
Max. absorbed power (kW)
Power supply voltage (V)
Power cable diameter
Type of cable
Connecting electric cable
Class
Degree of protection against humidity
Water pressure
(kPa)
The noise level of the appliance in operation is below 70 dB (A).
The "technical data" plate is positioned on the side panel of the appliance.
4. Instructions for the installer
The following instructions are aimed at the qualified installer, to ensure that he carries out the
installation, adjustment and maintenance operations as correctly as possible and according to
current legal regulations. Any operation must be performed with electrical power cut to the
appliance.
Before using the appliance, carefully remove the special adhesive film protecting the parts in
stainless steel. Do not leave any glue residues on the surfaces. If necessary, remove them at once,
with an appropriate solvent.
Positioning - Position the appliance perfectly horizontally on a table or similar support (the table
or support must be at least 85 cm above the floor). Position it at a distance of not less than 10
cm from the side and rear walls, to enable natural ventilating air to circulate freely around it. The
appliance is ventilated through specific openings on the metal walls of the outer housing , and
ensures efficiency and long-life. For this reason it is strictly forbidden to obstruct these ventilation
openings, even partially or for short periods. Failure to observe this specific prohibition releases
the manufacturer of the appliance from all responsibility and immediately voids any guarantee
rights for the said appliance, because its constructive conformity has been voluntarily
compromised. Furthermore, the appliance is not suitable for embedding and for grouped
positioning with other identical appliances.
Electrical connection - The appliance must be connected to the electrical mains according to
current legal regulations. Before making the connection, make sure of the following:
-
the voltage and frequency values of the power supply system match the values on the
"technical data" plate affixed on the appliance;
-
the limiting valve and the system are able to support the appliance's load (see the
"technical data" plate);
-
the power supply system has an adequate earth connection according to current legal
regulations;
page 4 ___________________________________________________________________________________________
784x752x634
50,4
4 – 2
16 - 8
3,2
3,4
230V~ (50/60Hz)
2
3x1,5 mm
H07RN-F
Tipo Y
I
IPX3
100-200