Descargar Imprimir esta página

Parkside PHD 150 F4 Traduccion Del Manual De Instrucciones Originales página 29

Ocultar thumbs Ver también para PHD 150 F4:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 71
Trouble shooting
Problem
Possible cause
Standard Vario nozzle (18)
is soiled
Severe pres-
sure fluctua-
tions
Standard Vario nozzle (18)
is blocked
ON / OFF switch (7) is
turned off
Pressure
Damaged power supply
cleaner is not
cable
operating
Mains fault
Air trapped in the pressure
Pressure clean-
cleaner
er does not
generate any
Drop in the water mains
pressure
pressure
Connections not fitted cor-
rectly
Leaks in the
water system
Water connection (14) leaks
Remedy
Rinse the standard Vario nozzle (18)
with water. If required, clean the nozzle
bore hole with a needle (see chapter en-
titled cleaning).
Remove the Standard Vario nozzle (18)
and ensure that the water can discharge
from the jet gun (16) unimpeded. In
other words, the device is working per-
fectly. The turbo dirt blaster (24) and the
rotating wash brush (2) do not normally
get blocked.
Check ON / OFF switch (7)
Switch off the equipment and disconnect
from the mains. Check power supply
cable for damage. If necessary have the
power supply cable replaced by a quali-
fied electrician.
Check the electrical system for conform-
ity with the data on the rating plate.
Switch on the equipment with the jet gun
and with no nozzle until bubble-free wa-
ter comes out.
Check the water mains.
Switch off the equipment and disconnect
from the mains. Reconnect the equipment
to the water pipes (cf. "Initial Operation/
Set-Up")
Switch off the equipment and discon-
nect from the mains. Replace the water
connection (14) inc. gasket (cf. "Spare
Parts")
I E
G B
2 9

Publicidad

loading