DISPOSAL OF WASTE APPLIANCES
At the end of its useful life, this product should not be disposed of with normal
household waste but should be taken to a collection point for the recycling of
electrical and electronic equipment. This is indicated by the symbol on the
product, operating instructions or packaging. The materials used in this appliance
are recyclable according to their marking. By reuse, recycling or applying other
forms of use of waste machines, you make a significant contribution to the
protection of our environment.
Your local administration will provide you with information about the appropriate
disposal point for used appliances.
TROUBLESHOOTING
Problem
The unit does
not work.
The "WATER
LOW" indicator
is on.
The compressor
does not start.
The compressor
runs but no ice
is produced.
Possible cause
a)
Voltage is too low.
b)
The ambient
temperature of the
environment in which
the device is located is
below 5
o
C.
a)
No water in the inlet.
b)
Water valve defective.
c)
Water pressure in the
water connection is
too low.
a)
No water in the
system.
b)
Full ice container.
a)
Refrigerant leakage -
leakage in the system.
b)
Clogged refrigerant fan
compressor.
c)
Defective fan.
Recommendation
a)
Turn off the device and
start it only when the
voltage has stabilized.
b)
Wait until the ambient
temperature rises or
install the device in a
place with a higher
ambient temperature.
a)
Check the water supply -
if there is water in the
system, restart the unit.
b)
Check the water inlet
valve.
c)
Make sure that the
water pressure in the
system is above 1.5 bar.
a)
Check the water
connection (supply hose
and water inlet valve).
b)
Empty the ice from the
container.
a)
Fill up the system with
the refrigerant and
check for leaks.
b)
Fill the system with
nitrogen (N
2
if it is blocked and
replace the filter (dryer).
) and check