05. Components
01 Mask
02 Filter
03 Regulator
04 Visor
05 Breathing tube
06 Hoses
07 Whistle
08 Safety valve
06
06. Warnings
Breathable quality compressed air, as defined in EN12021, MUST
be available. Regulator filter is for nuisance odours only. It will NOT
filter particulates and hazardous vapours.
The user must ensure the purity and identity of the breathing air supply at all times.
The air supply system should be equipped with an appropriately rated and adjusted pressure
relief safety valve.
If the face seal does not fit closely to the face then the stated levels of protection may not be
achieved.
This system should not be used below 0°C.
This system should not be used in or with oxygen or oxygen enriched air.
At very high work rates the pressure in the visor may become negative at peak inhalation flow.
The protection factor may not be achieved with persons with excessive facial hair or glasses.
Adequate protection may not be provided by the apparatus in certain highly toxic atmospheres.
This apparatus should not be used in areas where inhalation of the atmosphere, whilst escaping
in the event of failure of the air supply, would cause serious harm to health.
01
04
05
ENGLISH
03
07
08
02