Descargar Imprimir esta página

Scheppach AIR FORCE 5 Traduccion Del Manual De Instrucciones Originale página 25

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 62
• The compressor may only be used outdoor briefly
when the ambient conditions are dry.
• The compressor must always be kept dry and must
not be left outdoors after work is complete.
10. Attachment and operation
10.1 Mains connection
• The compressor can be connected to any 220 - 240
V~ / 50 Hz shock-proof socket which is protected by
a 15 A fuse.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor start-
up.
• At low temperatures below +5°C, sluggishness may
make starting difficult or impossible.
10.2 ON/OFF switch (fig. 1)
• To switch on the compressor, press the button (6)
on position I.
• To switch off the compressor, press the button (6)
on position 0.
10.3 Commissioning (Fig. 1)
1.
Connect the adapter of the compressed air hose
to the object you wish to inflate.
2.
Use one of the adapters (7, 8, 9) as and when
required and as described in 10.5.1.
3.
The display (2) now shows how much pressure is
currently in your item.
10.4 Setting the pressure (Fig. 1)
• The unit of the displayed pressure can be selected
with the button (4). The pressure can be displayed in
units of [bar], [PSI] or [kPa].
• You can set the pressure with buttons (3) and (5). Up
to max. 8 bar is possible.
• The button (5) allows the desired pressure to be re-
duced.
• The button (3) allows the desired pressure to be in-
creased.
• Switch the device on as described in 10.2. The com-
pressor will then pump until the preset pressure on
the display is reached, then it will switch off.
10.5 Establishing connections (fig. 2 - 4)
m Attention! Switch the device off for this.
10.5.1 Using the adapter set
The adapter set enables the following additional capa-
bilities:
• Pumping up balls with the help of the ball needle (7).
• The tyre valve adapter (9) enables bicycle tyres and
car tyres to be inflated.
• Filling pools, air mattresses, boats or similar swim-
ming accessories is also possible with the help of
the additional conical adapter (8).
Warning! Observe the information supplied by the
tire manufacturer and the vehicle manufacturer re-
lating to the recommended tire pressure.
Warning! This equipment is not calibrated! For a
calibrated measurement value, check the actual
tire pressure using a calibrated meter after you
have inflated the tires yourself, e.g. at a petrol sta-
tion.
10.5.2 12V socket (Fig. 8)
1.
Press the selector switch (11) to switch between
220-240 V AC and 12V DC.
2.
AC switch up: Device will be supplied with power
via the mains cable.
3.
DC switch down: Device will now be supplied with
DC power via the 12V connection cable.
4.
The compressor can be connected to a 12V sock-
et in the car. To do so, plug the connector (15) into
your car's socket.
11. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are
passed through windows or doors.
www.scheppach.com
GB | 25

Publicidad

loading

Este manual también es adecuado para:

5906142901