Descargar Imprimir esta página

ABB C576 Instrucciones De Servicio página 2

Aparatos de seguridad
Ocultar thumbs Ver también para C576:

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 4
Safety controlgears
Instructions
WARNING:
HAZARDOUS VOLTAGE
CAN CAUSE ELECTRICAL SHOCK
AND BURNS.
DISCONNECT POWER BEFORE PROCEEDING
WITH ANY WORK ON THIS EQUIPMENT.
Application
You can use the safety controlgear C576 in safety circuits as per VDE 0113
Part 1 (11.98) or EN 60 204-1 (11.98), e.g. with movable covers and guard
doors; the safety controlgear C577 in EMERGENCY STOP devices as per
EN 418. Depending on external connections, category 4 as per DIN EN
954-1 is achievable.
Functions and connections
The safety controlgears C576/C577 have two release circuits (safety cir-
cuits) configured as NO circuits. The number of release circuits can be
increased by adding one or more C579 expansion units. Three LEDs indicate
operating state and function.
When the EMERGENCY STOP button or the limit switch is unlocked and
when the ON button is pressed, the internal circuit of the safety controlgear
and the external contactors are checked for proper functioning.
On the C577, the ON circuit Y33, 34 is checked for short-circuit. This means
that a fault is detected when Y33, 34 is closed before the EMERGENCY
STOP button is closed.
Connect the EMERGENCY STOP button or the limit switch to terminals Y11,
12, 21, 22. Connect the ON button in series with the NC contacts of the
external contactors (feedback circuit) to terminals Y33, 34.
Terminal
Operating
A1
assignments
voltage
A2
Sensors
Y11, 12
Y21, 22
Y33, 34
Outputs
13, 14
23, 24
2
Cable lengths
for 2 x 1.5 mm
150 nF/km
Figures
Fig. I:
Dimension drawings (dimensions in mm)
Fig. II:
Installation
Fig. III:
Internal circuit
¿ PTC fuse
À Power pack
Á Control logic
 Channel 1
à Channel 2
Fig. IV:
C576 with Autostart for guard door monitoring,
category 4 per EN 954-1
Fig. V:
C577 with monitored start for
category 4 per EN 954-1
2
L/+
N/-
Channel 1
EMERGENCY STOP
or
limit switch
Channel 2
EMERGENCY STOP
or
limit switch
ON button, feedback circuit
Release circuit 1 (NO)
Release circuit 2 (NO)
max. 1000 m (total cable length for
sensors and power supply lines)
EMERGENCY STOP,
DIN EN 60 439 Part 1, VDE 0660 Part 500 (04.94)
Order No.: 1SAC 105 498 S4001
Operating states
LED
POWER Channel 1 Channel 2 PS
Fault
1. Switch supply voltage off.
clearance
2. Clear fault or replace device.
3. Switch supply voltage back on.
Technical data
Permissible ambient temperature T u
Operation/storage
Degree of protection to EN 60 529
Rated insulation voltage U i
Rated impulse withstand voltage U
Rated control supply voltage U s
Rated power
DC operating range
AC operating range
Shock resistance (half-sine) as per IEC 60068
Weight
Recovery time after EMERGENCY STOP
Release time after EMERGENCY STOP
Response time
Utilization
Rated operational
category
voltage U
e
(V)
as per DIN VDE 0660
Part 200, IEC 60947-5-1
AC-15
230
DC-13
24
115
230
Continuous current I
th
Short-circuit protection
Fuse links
for release circuit
Duty class
Control supply voltage
The safety controlgear is protected by an internal self-
healing PTC fuse (multifuse).
Be sure to fit the specified fuses. Otherwise safe interruption
in the event of a fault cannot be guaranteed.
For further data and accessories see Main Catalog, Part 1.
C576, C577
English
Operation
EMERGENCY
ON
STOP
ON
not activated
activated
activated
not activated
not activated
not activated
Faults
• Relay fusion-welded
• Motor contactor fusion-welded
• Defect in electronics
• Short-circuit in ON circuit
(only with C577)
Cross or ground faults in
EMERGENCY STOP
circuit (min. fault
current I
= 0.5 A; PTC fuse trips)
Kmin
-25 to +60°C/-40 to +80°C
IP 40, IP 20 at terminals
300 V
4 kV
imp
24 V AC/DC
1.5 W
0.85 to 1.2 x U s
0.85 to 1.1 x U s
8 g/10 ms
0.240 kg
C576
minimum 200 ms
C577
minimum 400 ms
max. 20 ms
C576
max. 80 ms
C577
max. 30 ms
Rated operational current I
with all release circuits loaded
(A)
50 °C
60 °C
5
4.5
5
4.5
0.2
0.2
0.1
0.1
5
4.5
DIAZED
gL(gG)
quick response
gL(gG)
Release
circuits
closed
open
open
open
e
70 °C
4
4
0.2
0.1
4
6 A
10 A
2 A

Publicidad

loading

Este manual también es adecuado para:

C577