Descargar Imprimir esta página

Astralpool SENA Guia De Inicio Rapido página 7

Ocultar thumbs Ver también para SENA:

Publicidad

EN) IMPORTANT SAFETY, INSTALLATION AND MAINTENANCE INFORMATION
• The appliance described in this manual is specially designed for the pre-filtering and recircula-
tion of water in swimming pools, with clean water at temperatures that do not exceed 35 ºC.
• This appliance is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety. Children should be supervised to ensure that they do not play with the appliance.
• This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user mainte-
nance shall not be made by children without supervision.
• Our pumps may only be assembled and installed in pools compliant with standards IEC/HD
60364-7-702 and required national rules. The installation should follow standard IEC/HD
60364-7-702 and required national rules for swimming pools. Consult your local dealer for
more information.
• If a self-priming pump is to be fitted above the water level, the pressure differential to the
pump suction pipe should not be higher than 0,015 MPa (1,5 mH
pipe is as short as possible as a longer pipe would increase suction time and the installation' s
load losses.
• The pump is intended to be used while fastened to a support or while secured in a specific
location in a horizontal position.
• Place a sump with an adequate outlet for the liquid where flooding is likely to occur.
• The pump can not be installed in Zone 0 (Z0) or Zone 1 (Z1). To see drawings refer to pages
30 and 31.
• See the maximum total head (H max), in metres in page 51.
• The unit should be connected to an alternating current supply (see data on the pump's
plate) with an earth connection, protected by a residual current device (RCD) with a rated
residual operating current that does not exceed 30 mA.
• A disconnector must be fitted to the fixed electrical installation in accordance to the
installation regulations.
O). Ensure that the suction
2
7

Publicidad

loading

Este manual también es adecuado para:

254612546225463254642546525466 ... Mostrar todo