TECHNICAL SPECIFICATIONS
Interfaces
WAN Port.
10/100BaseTX Fast Ethernet, (Auto MDI)
LAN Ports
4 x 10/100BaseTX Fast Ethernet (Auto MDI)
Indicators
Power (Green)
Status (Yellow)
WAN
Link/Activity (Green)
Connection and Activity
100M (Green)
Port operating at 10 or 100Mbps
LAN (per port)
Link/Activity (Green)
Connection and Activity
100M (Green)
Port operating at 10 or 100Mbps
Dimensions
153mm x 112.4mm x 31mm
REGULATORY COMPLIANCE
FCC Interference Statement
This device complies with Part 15 of FCC rule. Operation is subject to the following two conditions:
• This device may not cause harmful interference.
• This device must accept any interference received, including interference that may cause undesired operation.
This Corega BAR-SD Router has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used according to the instructions, may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which is found by turning the equipment off and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Increase the separation between the equipment or device.
• Connect the equipment to an outlet other than the receiver's.
• Consult a dealer or an experienced radio/TV technician for assistance.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum
distance 20cm between the radiator and your body.
CE Declaration of Conformity:
This equipment complies with the specifications relating to electromagnetic compatibility, EN 55022/A1 Class B, and EN 50082-1. This meets the reasonable protection
requirements set out in the European Council Directive on the approximation of the laws of the member states relating to Electromagnetic Compatibility Directive
(89/336/EEC).
Weight
230g
Power Supply
Input
220-250VAC
Output 5V DC, 2A
Temperature and Humidity
Operating 0-40°C, <80% Humidity, non-condensing
Storage
-20 – 60°C, <95% Humidity, non-condensing
Agency Approvals
FCC Class B
CE Class B
GOST- ME35
2