Descargar Imprimir esta página

Fulmo PLUS+ Manual De Instrucciones página 45

Publicidad

Idiomas disponibles

Idiomas disponibles

A. CONSTRUCTION AND FEATURES
Transportable terrace/garden stove with tank housing.
Powder coated steel or stainless steel housing.
Heat emission by the reflector.
B. SPECIFICATIONS
• Use only propane, butane or their mixtures.
• Maximum power: 13000 watts
• Minimum power: 5000 watts
• CONSUMPTION:
APPARATUS CATEGORY:
TYPES OF GAS
GAS PRESSURE
REGULATOR OUTLET
PRESSURE
• Use the appropriate regulator according to the regulator outlet pressure as shown in the table
above.
C. INJECTOR TABLE
DEVICE CATEGORY
TYPES OF GAS
GAS PRESSURE:
ENTRANCE
OF HEAT
(Hs):(Qn)
INJECTOR SIZE
The marking, e.g. 1.90 on the injector, indicates that the injector size is 1.90mm
The hose and regulator assembly must conform to local code standards.
The regulator outlet pressure must comply with the gas category corresponding to the injector table.
The device requires an approved hose of 0.6 m length.
I3+(28-30/37)
Butane
Propane
28-30mbar
37 mbar
30mbar
37 mbar
I3+(28-30/37)
Butane, propane
Butane
Propane
OR their derivatives
28-30mbar 37 mbar
30 mbar
13kW (945g/h)
1.90 mm for the main burner
0.18 mm for pilot burner
I3B/P(30)
Butane, propane
Butane, propane
OR their derivatives
OR their derivatives
30 mbar
50mbar
30 mbar
50mbar
I3B/P(30)
I3B/P(50)
Butane, propane
OR their derivatives
50mbar
1.70 mm for the main
burner 0.18 mm for
the pilot burner
I3B/P(50)
I3B/P(37)
Butane, propane
OR their derivatives
37mbar
37mbar
I3B/P(37)
Butane, propane
OR their derivatives
37 mbar
1.80 mm for the main
burner 0.18 mm for
pilot burner
45