6
COMMISSIONING
6.4
Process data structure
en
7
Troubleshooting
28
O P E R A T I N G I N S T R U C T I O N S | WTB4F SingleLine / DoubleLine
NOTE
Do not operate the teach-in button using sharp objects.
Please refer to the enclosed operating instructions for the IO-Link photoelectric sensor
for information about adjusting the IO-Link sensing range.
The sensor is adjusted and ready for operation.
WTx4Fx-xxxxxxA0Zxx:
Sensor which it is not possible to set: the sensor is adjusted and ready for operation.
WTB4FT-xxxxxxxxAxx / WTB4FA-xxxxxxxxAxx:
A00
A70
IO-Link
Process
data
Bit 0 / Data
type
Bit 1/ Data
Q
/ Boolean
L2
type
Bit.../
2...15 /
2...15 /
Descrip‐
[current
tion/Data
receiver
measure‐
type
level] /
UInt 14
value] /
UInt 14
Bit.../
Descrip‐
tion/Data
type
The Troubleshooting table indicates measures to be taken if the sensor stops working.
Table 14: Troubleshooting
LED/fault pattern
Green LED flashes
Switching outputs do not
behave in accordance with
table 6
Yellow LED lights up, no object
in the path of the beam
A71
A72
V1.1
2 bytes
Byte 0: Bit 15... 8
Byte 1: Bit 7... 0
Q
/ Boolean
L1
Qint.1 /
Boolean
2 ... 15 /
2 ... 15 /
[time
[counter
[length/
value] /
speed
ment
UInt 14
measure‐
ment] /
SInt14
Cause
IO-Link communication
1. IO-Link communication
2. Change of the configuration
3. Short-circuit
The sensing range distance is
too large
A73
A75
4 bytes
Byte 0: Bit 31... 24
Byte 1: Bit 13... 16
Byte 2: Bit 15... 8
Byte 3: Bit 7... 0
Q
/ Boo‐
Qint.1 / Boolean
L2
lean
2 /
2 ... 7 / [empty]
Qint.1 /
Boolean
3 ... 15 /
8 ... 31 / [carrier
[time
load] / UInt 24
measure‐
ment
value] /
UInt13
Measures
None
1. None
2. Adjustment of the configura‐
tion
3. Check electrical connections
Reduce the sensing range
8025300.1FCK/2022-02-14 | SICK