4. Use
4.1. Forseen use
The mixing stations are used for mixing and delivery
of pre-diluted detergent for cleaning stations or other
types of outlets. Water and detergent are mixed by a
dosing pump.
It is very important that the operational staff reads this
user guide thoroughly prior to installation and start of
operation. Operation as laid down in the directions for
use will ensure an optimum level of hygiene in your
factory and a minimum level of repair work.
4.2. Unforseen Use
The unit must only be used for mixing of water and
detergents for use in professional cleaning stations - all
other use will be considered unforseen use!
5. Installation
5.1. Directions for mounting of the Mixing Station
ATTENTION
1. The unit should be mounted in frost free rooms
only.
2. The unit is leveled by adjusting the feet. When the
unit is leveled the lock nuts on the feet are to be
tightened thoroughly.
3. The unit is fastened to the floor using a bolt
through the hole on each foot. It is sufficient to
fasten the feet in the corners.
5.2. Water connection
CAUTION
1. The unit must only be installed by skilled per-
sonell in this case Ecolab.
2. Before the station is connected to the water supply
pipe, the supply line should be rinsed carefully in
order to remove coarse impurities and metal shav-
ings.
3. The pressure loss in the supply line should be held
as low as possible by:
- avoid long supply pipes
- mounting of low pressure resistance ball valves and
- avoiding fittings with high pressure loss
4. When installing the piping, take care to avoid air
traps.
5.
Max. supply water temperature: 40°C
Min. water supply Mixing Station: 120 l/min
Max. allowed inlet water pressure: 7 bar
5.3. Bleeding the pump
WARNING
Never start up the supply pump before
the pump has been bled.
When the unit has been mounted and water has been
connected to the inlet side, the pump must be bled.
This is done by opening the bleeding screw in the top
of the pump. Operate the valve for the dosing pump
and fill the tank with water and bled the supply pump.
The pump must be bled until only water comes out of
the pump.
A
DETAIL A
13