Installation
PE
Information for electrically
skilled persons
Installation and electrical
connection
DANGER
Electrical shock on contact
with live parts in the installa-
tion environment.
Electrical shocks can be fatal.
Before working on the device, discon-
nect the power and cover live parts in
the area.
Wall mounting
Important: The safest motion detec-
tion is obtained when the device is
mounted and aligned laterally to the
walking direction and no obstacles
(such as trees and walls, for example)
obstruct the view.
Please note that the motion detector
must be protected by a 10 A
circuit breaker.
The installation site should be at least
50 cm from a light, since the latter's
L'
N
L
15
L = Phase conductor
N = Neutral conductor
L' = Service lead
PE = Protective-earth
heat radiation could result in false trig-
gering of the sensor. The installation
height should be approx. 2 m.
Remove mounting plate
vice. Do not undo the internal wiring
to the terminal block, but extract the
block by pulling it gently.
Insert the rubber plugs into the
mounting plate. Hold the mounting
plate against the wall and mark the
drill holes (paying attention to the
wiring arrangement in the wall), drill
the holes and insert the dowels.
In order to be able to perform a
switching operation, a power supply
lead with at least two phases must run
to the unit and a second lead out to
the consumer. The two rubber plugs
can be pierced for this purpose with a
screwdriver.
After passing the wiring through, the
mounting plate can be screwed in
place.
conductor
from de-