28 | Information about the appliance
2
Information about the
appliance
2.1
Product description
The buffer cylinder vessel is delivered fully assembled.
The thermal insulation and temperature sensors have to
be fitted.
There are two types of buffer cylinder
(
Fig. 4, page 52).
• Buffer cylinder
– BST 500-1000/80 Sr
– BST 500-1000/120 Sr
• Solar buffer cylinder
– BST 500-1000/80 SrSE
– BST 500-1000/120 SrSE
Both types of cylinder are available with 80 mm PU
flexible foam thermal insulation or 120 mm polyester
fleece thermal insulation.
The buffer cylinder is made from steel and equipped
with a temperature-sensitive return feed.
A back boiler or solid fuel boiler can be integrated via the
connections for the boiler and heating circuits.
The BST solar buffer cylinder additionally has a
connection for a solar thermal system and an electrical
immersion heater (
Fig. 4, page 52).
2.2
Standard delivery
Buffer cylinder, general
• Cylinder
• Technical documentation
• Thermal insulation
• Cylinder cover
• Upper and lower thermal insulation discs
• Flexible clamps for temperature sensors.
Buffer cylinder with 80 mm thermal insulation
• Thermal insulation for immersion heater connection
(only BST 500-1000/80 SrSE)
• Connection covers
Buffer cylinder with 120 mm thermal insulation
• Thermal insulation for immersion heater connection
(only BST 500-1000/120 SrSE)
Connection covers
2.3
Correct use
Due to their large volume, the BST buffer cylinders and
BST solar buffer cylinders are designed for central
heating backup.
6 720 800 379 (2011/03)
These buffer cylinders may only be filled with heating
water and used in sealed heating systems. The cylinders
are not suitable for use with potable water.
The buffer cylinders can be used for indirect DHW
heating via a freshwater station.
2.4
Tools, materials and auxiliary
equipment
A pallet truck, forklift truck or crane is required for
transportation.
2.5
Specification
2.5.1 BST buffer cylinder dimensions and
connections
Maximum permissible values BST 500–1000
Maximum operating pressure
Maximum operating temperature, heating
water
Table 31 BST maximum permissible values
Dimensions and
surface load
Height when
mm
tilted
Total weight
kg
when filled
Weight load
kg
per foot
Table 32 BST specification
2.5.2 BST solar buffer cylinder dimensions and
connections
Maximum permissible values BST 500–1000
Maximum operating pressure, solar indirect coil
Maximum operating pressure, heating water
Maximum operating temperature, solar
indirect coil
Maximum operating temperature, heating water
Table 33 BST maximum permissible values
1) Subject to the way the appliance is integrated into the
solar thermal system, individual protection may be
required (safety valve, expansion vessel).
bar
°C
BST
BST
500
750
BST 1000
1780
1740
1740
630
897
1176
210
299
392
1)
bar
bar
°C
°C
3
110
8
3
160