EN
CONNECTION
IMPORTANT: refrigerate the amplifier properly. To do this, make sure that the place where it is installed has
access to airflow and that the slots in the chassis are free of obstructions.
-
With the amplifier switched off, connect all audio sources AUX, CH, EMERG. INPUT.
-
Connect the speakers to the corresponding low impedance output* (4 Ω + COM) or 100 V line* (100 V +
COM) or to the stereo line output (LINE OUTPUT).
*IMPORTANT: for proper operation and performance of the equipment, use the correct power, impedance
and frequency limits. Before connecting to other equipment, be aware of the conditions required in a
HIGH IMPEDANCE (100 V) and LOW IMPEDANCE installation. More information can be found at
-
Check that the volume and gain controls are at minimum, connect the amplifier to power.
-
Turn on the amplifier and select input with the INPUT.
-
Finally, adjust all volume and gain and equalization controls (BASS and TREBLE).
INPUT PRIORITY
-
The EMERG input INPUT has the highest priority attenuating all other inputs when the input has a signal.
-
CH 1 input has priority over inputs CH 2, CH 3, CH 4, AUX 1 and AUX 2. This priority is by signal level
and can be selected with VOX control.
-
And CH 2, CH 3 and CH 4 inputs has priority over input AUX 1, AUX 2 and its priority is set with the VOX
control, just like as CH 1.
-
The REMOTE MUTE input attenuates all inputs except the EMERG input. INPUT when a contact closure
of its terminals is performed.
100 V LINE
LOW IMPEDANCE
fonestar.com/downloads/install_fonestar_es.pdf
EMERGENCY
EMERGENCY
EMERGENCY
EMERGENCY
- 4 -
MAX 240 W@100 V
MAX 240 W@100 V
MAX 240 W@4
MAX 240 W@4
230 V AC
230 V AC
230 V AC
230 V AC