Operation
6.2
Energy saving tips
Choose a well ventilated installation location which is protected against
direct sunlight.
Allow warm food to cool down first before placing it in the device to keep
cool.
Do not open the cooling device more often than necessary.
Do not leave the cooler unit open for longer than necessary.
Defrost the cooler once a layer of ice forms.
Avoid unnecessary low temperatures.
6.3
Connecting the cooler
The cooler can be operated with 12 V or 24 V DC.
A
NOTICE! Danger of damaging the device!
Disconnect the cooler and other consumer units from the battery
before you connect the battery to a quick charging device.
Overvoltage can damage the electronics of the device.
For safety reasons the cooler is equipped with an electronic system to pre-
vent the polarity reversal. This protects the cooler against short-circuiting
when connecting to a battery.
➤ Plug the 12/24-V connection cable (fig. 1 2, page 3) into the DC voltage
socket and also into the cigarette lighter or a 12 V or 24 V socket.
6.4
Using the battery monitor
If the cooler is operated when the vehicle ignition is switched off, the cooler
switches off automatically as soon as the supply voltage falls below a set
level. The cooler will switch back on once the battery has been recharged to
the restart voltage level.
A
NOTICE! Danger of damage!
When switched off by the battery monitor, the battery will no
longer be fully charged. Avoid starting repeatedly or operating
current consumers without longer charging phases. Ensure that
the battery is recharged.
In "HIGH" mode, the battery monitor responds faster than at the levels "LOW"
and "MED" (see the following table).