6.5. STOPPING THE GENERATOR:
6.5.1. Turn o the power switch of the electric equipment and unplug the cord from the
receptacle/socket of the generator.
6.5.2. Turn the circuit breaker to the "OFF" position.
6.5.3. Allow the engine to cool down for about three minutes with no load prior to
switching it o .
6.5.4. For recoil starter models turn the switch to the "OFF" position.
6.5.5. Electric starter models turn the key switch to the "OFF" position.
6.5.6. Close the fuel cock.
6.6. OIL SENSOR:
6.6.1. The oil sensor detects a drop in the oil level in
the crank case and automatically stops the engine
when oil level drops below a predetermined level.
6.6.2. When engine has stops automatically switch o
the generator's circuit breaker and check the oil level.
Re ll with engine oil to the upper level as instructed,
and then restart the engine.
6.6.3. If the engine does not start please recheck the
oil level.
CAUTION:
Do not remove the SENSOR PROBE when re lling with oil. Remove the oil ller cap on
the opposite side of carburetor.
ON
OFF
ON
CLOSE
OPEN
OIL SENSOR