•
After connecting the charger to the battery, you can connect the device's
plug to a power outlet - the device will automatically start charging the
battery with the lowest current ("A") and the built-in fan will start.
•
To change (increase/decrease) the current value while charging, press the
"Current Selection" button on the control panel. Press the button until the
charging current value allowed by your device is selected.
•
When the battery is fully charged, the "Full" indicator will light up on the
control panel and the graph will show the full battery with all % charge bars
lit (the "100%" bar may blink).
REGENERATION
The longer the regeneration time of the battery, the better, as it heats up
less. As a rule, the battery regeneration time is: 3-4 hours for 6V; 16-18 h
for 12V. The maximum regeneration time should not exceed 24 hours.
After this time, the device will automatically switch to the standard
charging/maintaining battery voltage mode.
IMPORTANT: during regeneration, check the condition of the battery
regularly as it can get hot! In this case, stop the process immediately and
turn off the device. One of the main reasons for the battery to heat up
during charging is too low electrolyte level and/or unsealed housing (see
more in "TROUBLESHOOTING").
•
To regenerate the battery, press the "Battery Recondition" button on the
control panel during normal charging. In this mode, the device emits an
alternating discrete sound confirming that the battery recondition process
is in progress.
•
To disable the recovery mode while it is in progress, press the "Battery
Recondition" button on the control panel and the device will switch to the
normal charging mode.
•
After the battery has been regenerated, the "Full" indicator will light up
and the graph will show the full battery with all % charge bars lit (the
"100%" bar may blink). Then the device will switch to the battery backup
mode (automatic recharging).
TROUBLESHOOTING
Problem
After connecting the
battery to the unit,
the display does not
work.
Possible cause
Defective or
inaccurately connected
terminals or battery
completely discharged
(defective).
Action
If the battery is
rechargeable, check
the connection of
the terminals with
the device cables
and/or correct the