Descargar Imprimir esta página

Tuthill FILL-RITE 900CDP Serie Manual De Instalación, Operación Y Seguridad Del Propietario página 5

Medidor digital de líquido

Publicidad

Idiomas disponibles

Idiomas disponibles

10. Pressing and holding the CAL
button for 2 seconds before
dispensing into a container will
cause the meter to skip a fill
operation and only change the
unit of measure.
IMPORTANT!
For maximum accuracy, try
to get as close as possible
to the dispensed volume
without changing flow rate.
11. The unit will default to a measured value based on the last calibration performed.
12. The left-most digit will begin blinking.
13. Use the TOTAL button to scroll from 0 to 9 until the desired number has been
selected.
14. Press and release the CAL button to move to the next digit.
15. Repeat Steps 3-4 until the
amount of dispensed fluid has
been entered.
16. If you make a mistake entering
a digit, press and release the
TOTAL button repeatedly until
the digit is active again.
17. Press and hold the CAL button
for 2 seconds to complete the
calibration process regardless
of the current digit selected.
18. If at the last digit and the CAL
button is pressed for less than
2 seconds, the process will roll
back to the left-most digit, but retain the current value. This allows the user to edit
an incorrect value.
19. An error check for gross calibration errors (+/- 15%) will be performed unless USER
units are selected. If an error is detected, the meter will display Err0 until a button is
pressed and the calibration process is aborted.
20. If the meter is left untouched for 2 minutes or the RESET button is pressed, the unit
will automatically exit Calibration Mode and ignore any changes.
Operating Instructions
For accurate measurement and to prevent meter
damage, dispenser and piping must always be filled
with liquid and be free of air. Calibrated the meter
per instructions in this manual prior to its use.
The Fill-Rite 900 Series Digital Meter face
incorporates three buttons that control all
the operation and calibration functions.
To turn the display on, or wake the meter from
"Sleep" mode, simply press any button on the
face. Dispensing fluid will also turn the meter
display on. The display can be illuminated by
pressing the "CAL" button. The display will
remain illuminated for 10 seconds.
5

Publicidad

loading