Do not operate the appliance if there are signs of
damage to the appliance, power cord, or any of the
accessories supplied. If the supply cord is damaged, it
must be replaced by the manufacturer, its service agent
or a similarly qualified person in order to avoid a hazard.
Do not operate the appliance if there are any signs of
damage to the appliance or accessories supplied.
Do not attempt to repair or adjust any electrical or
mechanical elements in the appliance. Doing so may be
unsafe and will void your warranty.
Never insert fingers or metal objects into the vents and
openings of the appliance
SPECIFIC INFORMATION REGARDING R290 REFRIGERANT GAS
― ―
WARNING: THE APPLIANCE MUST BE INSTALLED, OPERATED
AND STORED IN A ROOM WITH A FLOOR AREA LARGER
THAN 4M
.
2
This appliance contains 0.1kg (100g) of R290 refrigerant
gas.
R290 is a refrigerant gas that complies with the European
directive on the environment.
Do not puncture any part of refrigerant circuit.
Be aware R290 refrigerant is odourless and does not
have the odour normally associated with natural gas and
propane tanks.
Do not use means to accelerate the defrosting process
or to clean, other than those recommended by the
manufacturer.
6 of 80 | English
CAUTION
RISK OF FIRE
The appliance must be placed in an area without any
continuous sources of ignition such as open flames, gas,
or electrical appliances in operation.
Do not puncture and do not burn.
If the appliance is installed, operated or stored in a non-
ventilated area, the room must be designed to prevent
the accumulation of refrigerant leaks resulting in a risk of
fire or explosion due to ignition of the refrigerant caused
by electric heaters, stoves, or other sources of ignition.
The appliance must be stored in such a way as to
prevent mechanical failure.
Individuals who operate or work on the refrigerant circuit
must have the appropriate certification issued by an
accredited organisation that ensures competence in
handling refrigerants according to a specific evaluation
recognised by associations in the industry.
Maintenance and repairs that require the assistance
of other qualified personnel must be performed under
the supervision of an individual specified in the use of
flammable refrigerants.
SYMBOLS EXPLAINED
― ―
For indoor use only.
Equipment complies with the applicable EU safety requirements and regulations.
Please read instruction manual
and retain for future use.
English | 7 of 80