Safety Notes
6
6 Gloves should be worn during installation to
prevent crushing and cutting injuries.
6 The hot and cold supplies must be of equal
pressures.
Installation Instructions
• The fitting must be installed, flushed and tested
after the valid norms!
Technical Data
Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Rate of flow by 0,3 MPa:
Handspray flow rate:
Aerator flow rate:
anti-pollution function
Hansgrohe mixers can be used together with
hydraulically and thermically controlled continuous
flow heaters if the flow pressure is at least 0,15 MPa.
4
English
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
7 l/min
7 l/min
Assembly see page 32
Maintenance (see page 35)
The non return valves must be checked
regularly according to DIN EN 1717 in
accordance with national or regional
regulations (at least once a year).
To adjust the hot water limiter on single
lever mixers, please see page 40. No
adjustment is necessary when using a
continuous flow water heater.
Do not use silicone containing acetic
acid!
Dimensions (see page 31)
Spare parts (see page 38)
Operation (see page 37)
Cleaning (see page 34)
If the waterflow drops, clean the filter
located between hose and handspray.