7. MAINTENANCE
• The water in the tank will now leak out of the tank
Take care when compressed air is in the tank because the water can come out with some force.
Recommended pressure max. 1-2 Bar.
Clean the air filter
It is recommended to disassemble the suction filter every 50 operating hours and to clean the
filter element by blowing it with compressed air. It is recommended that the filter element is
replaced at least once a year if the compressor is working in a clean environment; more often if
the environment in which the compressor is situated is dusty.
Replacing/topping up oil
It is recommend to fully
replace the oil of the pump system within the first 50 operating hours.
• Unscrew the drain screw (4) on the sump lid, let all the oil run out and screw back the screw.
• Fill the oil via the upper hole of the sump lid until the level indicated on the inspection glass
has been reached.
• After each oil change or replenishment, keep the machine clean to ensure that there is no
residual oil on the product and reduce the risk of oil fire.
For replacement of oil the table below should be adhered to.
Type
Operating hours
Faults
Should a fault occur, e.g. after wear of a part, please contact the service address on the warranty
card.
EN
Check the oil level of the pump system every week and if necessary
top up. The synthetic oil has the advantage that it does not lose its
characteristics, either in summer or in winter periods.
Multigrade oil ISO 68/SAE 10W-30
50
12