Resumen de contenidos para STAR Water Systems SPCP02

  • Página 1 POOL COVER PUMP MODEL #SPCP02 Español p. 11 ATTACH YOUR RECEIPT HERE Purchase Date Serial Number Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-742-5044, 7:30 a.m. - 5:00 p.m., EST, Monday - Friday.
  • Página 2 ABOVE PUMPING LEVEL AMPS LENGTH NUMBER 0 FT. 5 FT. 10 FT. 15 FT. 20 FT. SPCP02 25 FT. 2400 2100 1680 1380 PERFORMANCE FROM SIDE OUTLET WITH GARDEN HOSE AT 0FT. ABOVE PUMPING LEVEL HOSE LENGTH GALLONS PER MINUTE GALLONS PER HOUR 25 FT.
  • Página 3 WARNING • ELECTRICAL SHOCK ALERT. Before installing this product, have the electrical circuit checked by an electrician to ensure proper grounding. All electrical installations must conform to the National Electric Code and all local codes. • ELECTRICAL SHOCK ALERT. Connect this product to a properly-grounded 115 volt outlet with a ground fault circuit interrupter (GFCI) device.
  • Página 4 PREPARATION Before beginning assembly of product, make sure all parts are present. Compare parts with package contents list. If any part is missing or damaged, do not attempt to assemble the product. Estimated Assembly Time: 5 minutes No Tools Required for Assembly. For best performance, use discharge hose of 50 ft.
  • Página 5 3. For best stability, attach garden hose to lower discharge. 1-1/4” top discharge may be used with proper support of discharge line and pump. If using garden hose (not included), thread the female end of the garden hose into the male end near the bottom of the pump.
  • Página 6 UTILITY PUMP INSTALLATION INSTRUCTIONS 1. To enable pump to fit into smaller spaces remove snap on base from pump by pulling the tab outward. This allows the pump to lift out of the base. 2. Attach garden hose adapter to the pump discharge and then connect garden hose to adapter.
  • Página 7 4. Plug pump into a properly grounded, ground fault circuit interrupter (GFCI) 115V AC power GFCI Outlet RESET outlet. TEST OPERATION 1. Water must be a minimum of 1-3/4-in deep for pump to operate. The pump will run for 15 seconds after it is plugged in. If water is being pumped during this 15 seconds, the pump will continue operating until water level drops to 1/8-in.
  • Página 8 CARE AND MAINTENANCE The motor housing of pump is completely sealed and requires no service. Disassembly of the motor housing or alteration of the power cord voids all warranty. 1. Periodically unplug pump to inspect the inlet and remove any debris. Make sure your hands are Unplug dry and that you are not standing in water.
  • Página 9 TROUBLESHOOTING PROBLEM POSSIBLE CAUSE CORRECTIVE ACTION Pump runs, 1. Hose kinked. 1. Straighten hose. but no water is 2. Defective pump. 2. Replace pump. discharged. 3. Discharge height too great. 3. Reduce discharge height. 4. Clogged inlet. 4. Clean inlet. 5.
  • Página 10 WARRANTY This product is warranted for two years from the date of purchase. Subject to the conditions hereinafter set forth, the manufacturer will repair or replace to the original consumer, any portion of the product which proves defective due to defective materials or workmanship. This warranty does not cover replacement parts for failure due to normal wear and tear.
  • Página 11 BOMBA DE CUBIERTA PARA PISCINA MODELO #SPCP02 ADJUNTE SU RECIBO AQUÍ Fecha de compra Número de serie ¿Preguntas, problemas, partes faltantes? Antes de acudir al minorista, llame a nuestro departamento de servicio al cliente al 1-800-742-5044, de lunes a viernes de 7:30 a.m. a...
  • Página 12 POR ENCIMA DEL NIVEL DE BOMBEO AMPERES ARTÍCULO CABLE 1,5 M 3,0 M 4,6 M 6,1 M SPCP02 25 FT. 9,084 7,949 6,359 5,224 2,271 FUNCIONAMIENTO DESDE LA SALIDA LATERAL CON MANGUERA DE JARDÍN 0 PIES POR ENCIMA DEL NIVEL DE BOMBEO...
  • Página 13 ADVERTENCIA • ALERTA DE DESCARGA ELÉCTRICA. Antes de instalar este producto, haga que un electricista revise su circuito para asegurarse de que la puesta a tierra sea adecuada. Todas las instalaciones eléctricas deben cumplir con el Código Nacional de Electricidad (NEC, por sus siglas en inglés) y con todos los códigos locales. •...
  • Página 14 PREPARACIÓN Antes de comenzar el ensamblaje del producto, asegúrese de tener todas las piezas. Compare las piezas con la lista del contenido del paquete. Si falta alguna pieza o está dañada, no intente ensamblar el producto. Tiempo estimado de ensamblaje 5 minutos No se necesitan herramientas para el ensamblaje.
  • Página 15 3. Para una mejor estabilidad, conecte una manguera de jardín a la descarga inferior. Se puede usar una descarga superior de 1-1/4” con el soporte adecuado de la línea de descarga y la bomba. Si usa una manguera de jardín (no incluida), enrosque el extremo hembra de la manguera de jardín en el extremo macho cerca de la parte inferior de la bomba.
  • Página 16 INSTRUCCIONES DE INSTALACIÓN DE BOMBA DE USO GENERAL 1. Para permitir que la bomba encaje en espacios más pequeños, retire el broche de la base de la bomba tirando de la pestaña hacia afuera. Esto permite que la bomba se desprenda de la base. 2.
  • Página 17 4. Enchufe la bomba en un tomacorriente de 115 VCA con interruptor de circuito por falla a tierra (GFCI) debidamente conectado a tierra. Tomacorriente RESET TEST con interruptor de circuito de falla de puesta a tierra (GFCI, por sus siglas en inglés) FUNCIONAMIENTO 1.
  • Página 18 CUIDADO Y MANTENIMIENTO La carcasa del motor de la bomba está completamente sellada y no requiere reparaciones. Si desensamble la carcasa del motor o altera el cable de alimentación, se anulará la garantía. 1. Desenchufe periódicamente la bomba para inspeccionar la entrada y retire cualquier Desenchufe desecho.
  • Página 19 SOLUCIÓN DE PROBLEMAS PROBLEMA CAUSA POSIBLE ACCIÓN CORRECTIVA La bomba 1. La manguera está torcida. 1. Enderece la manguera. funciona, pero no 2. La bomba está defectuosa. 2. Reemplace la bomba. sale agua. 3. Demasiada altura de descarga. 3. Disminuya la altura de descarga. 4.
  • Página 20 GARANTÍA Este producto se garantiza por un período de dos años a partir de la fecha de compra. Sujeto a las condiciones establecidas en el presente, el fabricante reparará o reemplazará, para el consumidor original, cualquier parte del producto que se compruebe que está defectuosa debido a defectos en los materiales o la mano de obra.