Installation Instructions
Installing the Flexible Conduit
Remove the conduit connection plate from the rear of the drawer body, and flip it as shown. (Use the 1⅛" hole.)
1. Prepare the conduit cord (Figure 1).
2. Install the conduit cord (Figure 2).
Conduit installations: Insert the strain relief (not included) in the 1⅛"conduit hole, thread the conduit cord through
the body of the strain relief, and fasten the ring, then reinstall the bracket.
Installing a 3-wire Conduit
•
Aluminum building wire may be used but must be rated for the correct amperage and voltage. Connect wires
according to Step 4 depending on the number of wires.
•
Wire used, location/enclosure of splices, etc., must follow good wiring practices and local codes.
Neutral terminal
Black
Black
24
English
INSTALL_DOP36C86DLS_DA_DG68-01510A.indb 24
INSTALL_DOP36C86DLS_DA_DG68-01510A.indb 24
Figure 1
1"
⅜"
1"
⅜"
3½"
3½"
3 wire
4 wire
Knockout surface
Conduit connection plate
Ground strap
White
Red
White
Red
Wire tips
1⅛"
1⅜"
Strain relief
1.
Loosen the three lower screws on the terminal block.
2.
Insert the white/neutral bare wire tip through the
bottom-center block opening. (Some models: the wire
inserted through the ground-strap opening into the
bottom-center block opening.)
3.
Insert the left and right wire tips into their
respective block openings.
4.
Tighten the screws to 35 – 50 in.-lbs.
(Any tighter may damage the wires.)
1⅜"
1⅛"
Figure 2
Ring
Body
2023-02-23 오전 9:57:50