3. ELECTRICAL SPECIFICATION
The accuracy specification is defined
as ± (percent of reading + digit) at 23±5°C, ≤ 80 %RH.
Safety Class - CAT III 600V
3-1 ACmA (True RMS)
Range
6.000mA
60.00mA
600.0mA
Zero correction: Fractions smaller than approximately
0.006 mA are calibrated to zero.
Low Pass Filter
6.000mA
60.00mA
600.0mA
3-2 ACA (True RMS)
6.000A
60.00A
Low Pass Filter
6.000A
60.00A
Resolution
0.001mA (1μA)
0.01mA (10μA)
0.1mA (100μA)
Range
Range
Resolution
Range
MILLIAMP CLAMP METER
Resolution
0.001mA
0.01mA
0.1mA
0.001A
0.01A
Resolution
0.001A
0.01A
KING INNOVATION
Accuracy
50 ~ 60Hz
1.0% + 8dgts
1.0% + 5dgts
Accuracy
2.0% + 8dgts
2.0% + 5dgts
Accuracy
50 ~ 60Hz
1.0% + 5dgts
Accuracy
2.0% + 5dgts
60 ~ 500Hz
2.0% + 8dgts
2.0% + 5dgts
60 ~ 500Hz
2.0% + 5dgts