SAFETY INTRODUCTION
Please note the load power
Please refer to the data we suggest to ensure the normal total working hours of DM-1225
1 If DM-1225 is installed in a rack, please make sure the rack is airy.
Otherwise the machine will become over-heat and result in the mis-fuction.
2 DM-1225 The max output of each channel is 20A : For testing (do not over 30 minutes)
3 DM-1225 The max output of each channel is 16A: For several hours use.
(Theaters, stage).
4 DM-1225 The output of each channel is 12A: Can work for the whole year without
switching off. (Is suitable for hotels, restaurants and building).
CONDICIONES DE TRABAJO AMBIENTAL
1 Temperature: Under 35 C
2 If the machine is installed in a rack, then the temperature inside the rack must be
under 45 C.
3 Humidity: 40%----80%
CHAPTER 1 INTRODUCTION OF DM-1225
FEATURE
Automatic frecuency sensor can detec power frecuency (45Hz--63Hz) in differents
areas and stabilizes the dimming output.
The thermo-controlled fan will be activated automatically when the temperature is over
45 C.
The intelligent thermo-protection will cease the output when the temperature is over
85 C and restart output below 65 C.
Each channel can be set as dimming r non-dimming.
Self-testing function to test without a console.
Dimmer level and internal temperature monitor.
Warm up function to protect the loads. (Warm up setting 0%--6%)
Output can be limited from 50% to 100% for overload protection.
Each channel is equipped with a N.F.M.
Easy wiring.
9