Application
Can be used in conjunction with: Pressurised storage
heaters, thermally and hydraulically controlled
instantaneous heaters.
Operation with low-pressure displacement water
heaters is not possible.
Technical Data:
x
Flow pressure: min. 0.5 bar - recommended 1 - 5 bar
x
Operating pressure
x
Test pressure
If static pressure exceeds 5 bar, a pressure reducing
valve must be fitted.
Avoid major pressure differences between hot and
cold water supply.
x
Flow rate at 3 bar flow pressure:
32 366, 32 367, 33 347, 33 348
x
Temperature
Hot water inlet
Recommended:
Scalding protection possible by fitting a temperature
limiter (see replacement parts fold-out page II, order
no.: 46 375)
x
Water connection
Installation
Flush pipes thoroughly.
Installation and connection, see fold-out page III,
Fig. [1] and [2].
The base (A) is only fitted on product no. 32 366
and 33 347.
Refer to the dimensional drawing on fold-out page I.
Lift rod (B) must be inserted into the mixer body during
installation.
Install pop-up waste set (28 910), see fold-out page II.
Seal plug-hole rim.
Open cold and hot-water supply and check
connections for leakage.
Check fitting for correct operation, see Fig. [3].
Flow rate limiter
This mixer is fitted with an adjustable flow rate limiter,
permitting an infinitely variable individual reduction in
the flow rate.
The highest possible flow rate is set by the factory
before despatch.
The use of flow rate limiters in combination with
hydraulic instantaneous water heaters is not
recommended.
To activate, see "Replacing the cartridge" steps 1 to 3,
max. 10 bar
Figs. [4] and [5].
16 bar
Maintenance
Inspect and clean all parts, replace as necessary and
grease with Grohe special grease (order no. 18 012).
Shut off cold and hot water supply.
approx. 12 l/min
q
max. 80
C
I. Replacing the cartridge, see Fig. [4].
q
(energy saving) 60
C
1. Lever out plug (C).
2. Loosen set screw (D) with 3mm socket spanner
and detach lever (E).
3. Remove cap (F).
4. Remove screw union (G) with 32mm spanner.
cold - right
5. Replace either complete cartridge (H)
or seals (H1).
hot - left
Assemble in reverse order.
Observe the correct installation position.
Ensure that the cartridge seals (H1) engage in the
grooves and the locating pins at the base of the
cartridge slot into the apertures on the housing.
Install screw union (G) and tighten.
II. Unscrew and clean mousseur (13 929) /
nozzle (46 493), see fold-out page II.
Replacement parts, see fold-out page II ( * = special
accessories).
Care
For directions on the care of this fitting, please refer to
the accompanying Care Instructions.