pedestrians. The connection of
improper
electrical
improper installation, will cause
the electrical shock hazard.
►1.22. Conditions of use:
A) Air temperature: 18°C to 45°C;
Water temperature: <45°C.
B) The air supply must be free
of dust, pollutants, or additional
cleaning should be used.
►►2. UNPACKING
►2.1. Remove all packaging materials
used to wrap and deliver the appliance
and dispose of them in compliance
with the Standards in force.
►2.2. Extract all items from the
packaging.
►2.3. Verify if damage undergone
during transport. If the appliance
appears damaged, inform the dealer,
where the purchase was made,
immediately.
►►3. ASSEMBLY
The device is equipped with wheels to
facilitate handling. Depending on the
model, wheels can be found already
installed or not. Components equipped
with relative nuts and bolts are found
inside the packaging (Fig. 1).
►►4. OPERATION
WARNING: Thoroughly read the
"INFORMATION
SAFETY", before switching the
appliance on.
WARNING: Only use clean water to
prevent failures or other anomalies.
Figures and texts of this book are protected by COPYRIGHT.
All manuals and user guides at all-guides.com
voltage
or
REGARDING
WARNING: Verify if your electronic
system
is
earthed
Connection to the mains must
be made in compliance with the
National Standards in force. Power
the appliance only with voltage and
frequency as specified on the data
plate.
NOTE:
These
connected to the water mains, by
connecting the pipe to the fitting
(Fig. 10).
►►4.1. SWITCHING ON:
►4.1.1. Open the tank door (Fig. 2).
►4.1.2. Fill the tank with water (Fig. 3);
water level must be within MIN and
MAX level of the graduated scale,
placed at the side of the appliance
(Fig. 4), in order to prevent risks.
►4.1.3. Close the tank door (Fig. 5).
►4.1.4. Connect the power plug to the
mains (Fig. 6).
►4.1.5. Press the ON/OFF button to
switch on the appliance (Fig. 9).
►►4.2. CONTROL PANEL, USE
AND FUNCTIONS (Fig. 7-8):
►ON/OFF: It allows switching ON or
OFF the appliance.
►SPEED:
Allows
decreasing the appliance ventilation
speed. Three speeds can be selected
- LOW, MID and HIGH.
►COOL: It enables or disables the
cooling mode.
►SWING: It enables or disables the
automatic vertical oscillation of the
flaps to direct the air flow.
►ANION: It enables or disables the
ionisation mode, i.e. release of
negative ions into the environment, in
order to make air healthier.
correctly.