LED Indicators
Indicator
Color
Green ON
Flash in Green
Blue ON
Red ON
Cable Requirements
Cable
Three core outdoor AC
cable
AC Cable
Five core outdoor AC cable
RCD Requirements
Charger
RCD Type
Model
GW7K-HCA
GW11K-
TYPE A
HCA
GW22K-
HCA
Explanation
The charger is standby.
The system of the charger is upgrading.
The charger is in charging.
A fault has occurred.
Type
GW7K-HCA
• Copper, -30°C ~ +50°C, 450/750V
• Outer diameter: 11~17mm
• Conductor cross-sectional area: 6mm
GW11K-HCA
• Copper, -30°C ~ +50°C, 450/750V
• Outer diameter: 11~17mm
• Conductor cross-sectional area: 2.5mm
GW22K-HCA
• Copper, -30°C ~ +50°C, 450/750V
• Outer diameter: 11~17mm
• Conductor cross-sectional area: 6mm
RCD
Instantaneous
Tripping
Characteristic
C
Cable Specification
RCD
Tripping Current
40A
30mA
25A
40A
3
2
2
2
RCD
RCD
Norminal
Norminal
Current
Voltage
AC 230V
(2P)
AC 400V
(4P)
AC 400V
(4P)