Descargar Imprimir esta página

Atlas Copco ETV STB63-70-13-IRC-W Instrucciones Del Producto página 6

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 36
Safety and operating instructions
Installation
Installation
For installation guidelines refer to POWER FOCUS manual (9836 3123 01).
The tool calibration torque is stored in non-volatile memory in the tool.
Any changes made to the tool calibration torque in the POWER FOCUS
will update the stored value in the tool.
Model
ETV STB32/33/34
ETV STB62/63/64
ETP STB32/33/34
Handling
Operating
As tightening torque increase the reaction force build up equally. Make sure
that the tool is in correct working order and that the controller is correctly pro-
grammed to avoid unexpected behaviour from the tool, which may result in op-
erator injury.
ETV/ETD: Check that the tool is in the correct running direction by turn-
ing the reverse ring,
• Clockwise = Tool forward.
• Anti clockwise = Tool reverse
ETP: Check that the tool is in the correct running direction by pushing the re-
vers switch.
The soft-start function facilitates entering the screw head and thread.
The duration of the soft start is adjustable, see the manual for the POWER FO-
CUS/ drive unit.
The tool is equipped with four LED´s for specific tasks:
• Connection LED: Indicates connection to Power Focus
• Battery LED: Indicates battery status (flashing light for low and fixed light
for empty battery)
• Batch LED: Indicated Batch done
• Alarm LED: A failure/event is detected
Preventing ESD problems
The components inside the tool and controller are sensitive to electrostatic dis-
charge. To avoid future malfunction, make sure that service and maintenance is
carried out in an ESD approved work environment. The figure below shows an
example of an appropriate service work station.
6
EN
Battery
Li-ion 18V / 2.6Ah
Li-ion 30V / 2.6Ah
Li-ion 18V / 2.6Ah
© Atlas Copco Industrial Technique AB - 9836 899800 00
ETV STB63-70-13-IRC-W

Publicidad

loading